AW 139 Fuel Flashcards
How does fuel crossfeeding occur, with the crossfeed switch at NORMAL?
b. Automatically with a FUEL PUMP caution.
What feature does the FUEL SYSTEM have when fuel crossfeeding occurs with the crossfeed switch at NORMAL ?
c. Part of a fuel content in one tank can not be supplied with the operating pump
What action should be carried out after a 1 FUEL PUMP caution?
b. The XFEED switch should be set to CLOSE if the fuel pressure on #1 system is not recovered
When fuel crossfeed occurs with the switch at NORMAL:
c. Part of fuel content in one tank can´t be supplied with the operating pump
In case of 1 FUEL PUMP caution:
c. Continue flight
Fuel manifold is provided with:
c. Shut-off valves, cross-feed valve, pressure transmitter
In case of FUEL PROBE caution:
a. Continue flight
In case of FCU FAIL caution:
a. Continue flight
With the A/C not electrically powered , the shut-off valve and the cross-feed valve indicators:
c. Will be black
In case of fire into the no.1 engine bay, the relative shut-off valve:
c. Is closed automatically only when the ENG 1 FIRE EXTING is armed
The cross-feed valve switch is set to CLOSED. The booster pump failure
a. Has no influence on it