ATA70 - Power plant Flashcards
119. The thrust limit is computed by : The FMGC according to the AP/FD MODE The FADEC (ECU) according to the THRUST LEVER position The ECU according to the AP/FD MODE The FMGC according to the ECU order
The FADEC (ECU) according to the THRUST LEVER position
- Which valve ensure an adequate fuel flow :
The HP FUEL SHUT-OFF VALVE
The LP FUEL SHUT-OFF VALVE
The FUEL METERING UNIT
The FUEL METERING UNIT
- What device provides direct closure of the HP and LP SHUT-OFF VALVES :
The MASTER SWITCH at OFF position
The ECU
HMU
The MASTER SWITCH at OFF position
- What is the minimum starting oil temperature :
- 40°C
- 10°C
0°C
- 40°C
- In manual mode, when the THRUST LEVERS are between the CLIMB DETENT and
IDLE :
Each position of the levers correspond to a N1
N1 climb is selected disregarding THRUST LEVER positions
IDLE THRUST is selected
THRUST is locked
Each position of the levers correspond to a N1
- On the ground the start sequence is automatically aborted :
There is no automatic start sequence
In case of hot start, hung start, stall or no light up
Only in case of no light up
In case of hot start, hung start, stall or no light up
- Ignition comes on automatically when N2 reaches :
0%
25%
16%
16%
- What is the EGT limit at TOGA power setting (CFM 56-B4)?
725°C on 1 engine or 715°C on both engines running
855°C during 5 min ( 10 min on 1 engine )
950°C during 5 min ( 10 min on 1 engine )
950°C during 5 min ( 10 min on 1 engine )
- LVR MCT amber message (in the left part of the FMA) means :
THRUST LEVERS are not in MCT position after engine failure
THRUST LEVERS are not in CLB position after TAKE OFF
THRUST LEVERS are not in MCT position after engine failure
- What is the maximun starter operating time :
8 min followed by 15 min of no operation
5 min followed by 20 sec of no operation
2 min followed by 20 sec of no operation
2 min followed by 20 sec of no operation
- The LOW PRESSURE ROTOR (N1) consist of (CFM 56-B4) :
A front FAN - 9 STAGE BOOSTER - 5 STAGE LP TURBINE
A front FAN (1 STAGE) - 4 STAGE LP COMPRESSOR - 4 STAGE LP TURBINE
A front FAN (1 STAGE) - 4 STAGE LP COMPRESSOR - 4 STAGE LP TURBINE
- How is the oil cooled ?
By the engine FUEL/OIL heat exchanger
By oil recirculation and the FUEL/OIL heat exchanger
By the air/oil heat exchanger only
By the engine FUEL/OIL heat exchanger
- In AUTOTHRUST MODE the THRUST computed by the FMGC is limited :
By the mode engaged on the FCU
To the value corresponding to the TLA by the FADEC
By the FMGC it self
To the value corresponding to the TLA by the FADEC
- What is the minimum oil pressure before warning on ENGINE ECAM SD page :
13 PSI
40 PSI
Variable according to oil temperature
13 PSI
- The FADEC automatically select continuous ignition in the following cases :
Flame out detected
Engine running and ignition delay during start
Both answers are correct
Both answers are correct
- Is the engine still supplied in case of oil filter clog :
Yes, by using the oil coming from the IDG cooling tank line
Yes, by BY-PASSING the OIL FILTER (BY-PASS VALVE)
No, the engine stops
Yes, by BY-PASSING the OIL FILTER (BY-PASS VALVE)
135. The max continuous OIL TEMP limit may be exceeded. What is the limit and in which conditions ? 155°C for less than 15 min 140°C without any delay Both answers are correct
Both answers are correct
- In flight, if the INSTINCTIVE DISCONNECT P/B is pressed for more than 15 sec, the
A/THR including ALPHA FLOOR is definitively lost :
Right
Wrong
Right
- What is the FADEC ?
An Engine Control Box (ECB)
A THRUST CONTROL ENG UNIT (EIU)
The Full Autority Digital Control and its peripherical sensors and components
The Full Autority Digital Control and its peripherical sensors and components
- Reduced FLEX TAKE-OFF THRUST is not permitted :
If outside air temp is lower than corrected temp
On contaminated runway or with one (or more) reverser INOP
If outside air temp is higher than TREF (ISA+15°c)
On contaminated runway or with one (or more) reverser INOP
139. The maximun REVERSE THRUST may be used down to : A/C stop according to EGT LIMIT 70 kts ( IDLE REVERSE down to A/C stop ) 40 kts ( IDLE REVERSE down to A/C stop )
70 kts ( IDLE REVERSE down to A/C stop )
- EGT indication pulses red on ECAM E/WD when EGT is higher than (CFM 56-B4) :
725°C
855°C
950°C
950°C
- THRUST REVERSERS are actuated by :
hydraulic actuators : GREEN for ENG 1, YELLOW for ENG 2
hydraulic actuators : BLUE for ENG 1, YELLOW for ENG 2
pneumatic actuators
hydraulic actuators : GREEN for ENG 1, YELLOW for ENG 2
- In order to select MCT after an engine failure on a FLEX TAKE-OFF :
As the LEVER THROTTLES are in FLEX DETENT : MCT selection is automatic
LEVER THROTTLES may be moved to TOGA or CL detent then back to MCT
position
LEVER THROTTLES may be moved to TOGA or CL detent then back to MCT position