ATA36 - Pneumatic Flashcards
1
Q
364. Temperature regulation is achieved by the PRECOOLER which regulates and limits the temperature at : 150° C 85° C 200° C
A
200° C
2
Q
- AIR BLEED from the engine is :
Cooled in a heat exchanger by cooling AIR BLEED from FAN section
Cooled by using ambient air
Only cooled in air conditionning packs
A
Cooled in a heat exchanger by cooling AIR BLEED from FAN section
3
Q
- Which source operates the BLEED VALVE ?
Pneumatic
Electric
Both answers are correct
A
Pneumatic
4
Q
- HIGH PRESSURE air is supplied from :
Engine 1 and 2 BLEED system, APU load compressor, HP ground connection
Engine 1 and 2 BLEED system
Engine 1 and 2 BLEED system and APU load compressor
A
Engine 1 and 2 BLEED system, APU load compressor, HP ground connection
5
Q
- CROSSBLEED VALVE is provided with 2 electrical motors :
1 for the AUTOMATIC MODE, the other one for the MANUAL MODE
2 for the AUTOMATIC MODE
2 for the MANUAL MODE
A
1 for the AUTOMATIC MODE, the other one for the MANUAL MODE
6
Q
- PNEUMATIC SYSTEM operation is controlled and monitored by :
1 BLEED MONITORING COMPUTER
2 BLEED VALVE COMPUTERS
2 BLEED MONITORING COMPUTERS
A
2 BLEED MONITORING COMPUTERS
7
Q
- Which source controls the ENG BLEED VALVE ?
PNEUMATIC by the precooler FAN AIR VALVE
ELECTRIC by its associated BMC
A
ELECTRIC by its associated BMC
8
Q
- Can you control the HP VALVE position through the AIR BLEED COCKPIT PANEL ?
Yes
No
A
Yes
9
Q
- If the BLEED VALVE closes , the HP VALVE :
Opens automatically
Closes automatically
A
Closes automatically
10
Q
- What happens when pressure and temperature are not sufficient to supply the
corresponding ENGINE BLEED VALVE ?
IP VALVE closes
HP VALVE opens, IP STAGE closes
HP VALVE opens, IP STAGE remains in the same configuration
A
HP VALVE opens, IP STAGE closes
11
Q
- With engines and APU running and APU BLEED VALVE selected ON , select the
correct statement :
ENGINE BLEED VALVE opens, X BLEED VALVE opens, APU BLEED VALVE
closes
ENGINE BLEED VALVE closes, X BLEED VALVE opens, APU BLEED VALVE
opens
ENGINE BLEED VALVE opens, X BLEED VALVE closes, APU BLEED VALVE
opens
A
ENGINE BLEED VALVE closes, X BLEED VALVE opens, APU BLEED VALVE opens