ATA49 - APU Flashcards
1
Q
- APU may be used :
On ground and in flight
On ground and during TAKE-OFF
Only on ground
A
On ground and in flight
2
Q
- APU MASTER SW P/B FAULT amber ; ECAM shows APU AUTO SHUT DOWN ; it
means :
An automatic APU shut down after a reason other than a fire
APU FAULT without AUTO shutdown
APU is runnig while Ground Power Unit is connected to the aircraft
A
An automatic APU shut down after a reason other than a fire
3
Q
- APU FUEL PUMP is used :
For batteries APU start up
When tank pump pressure is not available
Both answers are correct
A
Both answers are correct
4
Q
- In case of an APU FIRE on ground :
APU can only be stopped from the cockpit
Fire extinguisher bottle can be operated from the external POWER PANEL
APU shut down and extinguishing agent discharge are fully automatic
A
APU shut down and extinguishing agent discharge are fully automatic
5
Q
- On ground, APU should provide :
ELEC POWER + HYDRAULIC POWER
ELEC POWER + BLEED AIR
A
ELEC POWER + BLEED AIR
6
Q
- When APU MASTER SW is released, APU normally stops :
With no delay in all cases
With a delay in all cases
After a 2 minutes cooling period if APU BLEED AIR was used
A
After a 2 minutes cooling period if APU BLEED AIR was used
7
Q
- When APU is running, APU FUEL PUMP :
Runs if tank pump pressure is not sufficient
Runs all the time
Runs only in flight
A
Runs if tank pump pressure is not sufficient
8
Q
- Can you start the APU using the aircraft BATTERIES :
Yes
No
A
Yes
9
Q
- APU N indication becomes amber on ECAM SD, when :
N >107%
N >102%
N >99%
A
N >102%
10
Q
- The APU is supplied from the :
Right fuel feed line
Left fuel feed line
A
Left fuel feed line
11
Q
- APU BLEED AIR is controlled :
By Electronic Control Box (ECB)
Not controlled
By APU BLEED VALVE which operates as shut off valve
A
By Electronic Control Box (ECB)
12
Q
- APU start up is available :
Only on aircraft batteries
On normal AC electric system,with batteries buffer
Both answers are correct
A
Both answers are correct
13
Q
- What does “AVAIL” light mean ?
ECB self test is completed
APU N is above 99,5% or 2 sec after N reaches 95%
APU may be started up
A
APU N is above 99,5% or 2 sec after N reaches 95%
14
Q
- APU starts after :
Master switch ON and flap open
Master switch ON and START P/B ON
Master switch ON, START P/B ON and flap open
A
Master switch ON, START P/B ON and flap open
15
Q
- APU EGT indication becomes red on ECAM SD when :
EGT > 515°C (APU RUNNING)
EGT > 1038°C (APU START UP)
EGT > 675°C (APU RUNNING) or EGT > 1090°C (APU START UP)
A
EGT > 675°C (APU RUNNING) or EGT > 1090°C (APU START UP)