APU Flashcards

1
Q

What will cause the APU to auto shutdown on the ground

A
Under speed
FADEC Fault
Over speed
Sensor Fail
High Oil Temperature 
EGT Fault
Low Oil Pressure
Fire
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What will cause the APU to auto shutdown in the Air

A

Underspeed
FADEC
Overspeed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When you shutdown the APU what Source is taken away immediately

A

Bleed Source

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What electricity output does the APU give you

A

115Vac, 40kva, 400hz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What battery powers APU FADEC

A

BATT 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When only DC power is available what provides fuel to the APU? From which Tank

A

The DC Fuel pump on the right wing.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When AC Power is available and engine is off what pump provides fuel to the APU?

A

The AC Fuel Pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Is it possible to provide Fuel to the APU from the left wing tank?

A

Yes from the Fuel crossfeed Valve.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

APU can supply electrical power up to what altitude

A

33,000 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

APU can supply bleed for engine starting up to what altitude?

A

21,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

APU can supply Bleed Air up to what Altitude

A

15,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Max altitude to start the APU

A

30,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What happens When you turn the APU Knob to on?

A

Powers the FADEC and opens the fuel SOV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How long should you wait before starting the APU after power has been introduced to EICAS

A

30 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

3 seconds after the APU has reached 95% what is available

A

Bleed and Electrical loading.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When you shutdown the APU when do you loose Bleeds and when do you loose electrical.

A

Bleeds - Immediately

Electrical - After 1 minute cool down.

17
Q

How do you know when the APU shutdown cool down period is over?

A

APU SHUTTING DOWN message disappears.

18
Q

What happens if you turn the APU Knob back to ON while during the shutdown period?

A

It cancels the shutdown and gives you back the APU.

19
Q

Can the APU be started with BATT 1 Dead?

A

No, you need At least BATT 1 and DC Ground Power to replace a dead BATT 2.

20
Q

When shutting down APU. What are you looking for before turning off the batteries

A

Wait until you have the cyan off message