APU Flashcards
APU is a
Sundstrand APS 2300, Single stage gas turbine engine
APU starter duty cycle
1st/2nd Attempts 1 min ON / 5 min OFF
3rd Attempt 1 min ON / 5 min OFF
Start temperature
min -54 C
Max start altitude
30,000 feet
Max operation altitude
33,000 feet
Max operation electric gen altitude
33,000 feet
Max operational bleed air
15,000 feet
Max alt to assist engine start
21,000 feet
Max rotor speed
108%
Max EGT
Start 1032 C
Continuous 717 C
How is APU controlled?
Controlled by its own FADEC system
How is APU supplied with fuel?
Fuel comes for the right wing tank, can also be fed from the left wing wit the Crossed valve
APU bleed air provides air for?
- Air conditioning
- Pressurization
- Water Pressure
When APU is started when is electrics and pneumatics available?
- Usually around 95% plus 3 seconds
How many starts can you get off the batteries?
- Only 2 starts from the 10 minute batteries