APU Flashcards
Q 01: To start the APU the:
A: BAT 1 and 2 push buttons must be selected to ON
B: BAT 1 and 2 push buttons do not need to be selected ON if external power is available.
C: Both are correct
A
Q 02: The Electronic Control Box (ECB) is primarily a full authority digital electronic controller that performs the APU system logic for all modes of APU operation such as:
A: Sequence and monitoring of start.
B: Speed and temperature monitoring.
C: Monitoring of bleed air and shut down.
D: All of the above.
D
Q 03: When the APU Master Switch is released, a normal APU shutdown occurs:
A: Without delay in all cases.
B: With a delay, in all cases.
C: With a delay if the bleed air was in use.
C
Q 04: When selected on, the APU START push button, will:
A: Connect the APU generator to the aircraft electrical system.
B: Start the APU if the APU MASTER SW was previously selected ON.
C: Open the air intake flap and supply fuel pressure.
B
Q 05: The APU has an integral independent lubrication system for lubrication and cooling.
A: True.
B: False.
A
Q 06: The ECB (Electronic Control Box) controls the fuel flow.
A: True.
B: False.
A
Q 07: When the APU MASTER SW is selected ON:
A: The APU computer automatically completes a self-test, opens the air intake flap and supplies fuel pressure.
B: The APU computer automatically starts the APU.
C: Connects the APU generator to the aircraft electrical system.
D: The APU door opens.
A
Q 08: The APU MASTER SW FAULT light will illuminate:
A: When APU low oil pressure is detected.
B: When an automatic shutdown of the APU occurs.
C: For an APU overheat or APU fire.
D: If the batteries are selected OFF while the APU is operating.
B
Q 09: Will the APU bleed valve close automatically during climb? Will it reopen during descent?
A: Yes
B: No
B
Q 10: The APU system page will appear on the ECAM:
A: When selected by the crew.
B: Automatically whenever the APU is started and AC power is available.
C: Both are correct.
C
Q 11: If APU bleed was used, after a manual shut down sequence, the APU: A: Stops immediately B: Keeps running for 4 minutes C: Keeps running for 2 minutes D: Keeps running for 60 seconds
D
Q 12: With the engines off, if the AVAIL light is illuminated on both the APU START push button and the EXT PWR push button, what is the source of electrical power for the aircraft busses?
A: It is not possible to determine without checking the ECAM.
B: The aircraft batteries
C: The APU.
D: External power
C
Q 13: BAT 1 and 2 push buttons do not need to be selected ON if external power is available.
A: It is normally left in the lights out position.
B: When selected OFF, the APU generator is de-energized.
C: Both are correct.
C
Q 14: What is the maximum altitude at which the APU may be started using the batteries only? A: 15, 000 ft B: 20, 000 ft C: 25, 000 ft D: 39, 000 ft
C
Q 15: When the APU is running, the APU fuel pump:
A: Runs when tank pumps pressure is not sufficient.
B: Runs all time
C: Runs only in flight.
D: Runs when the APU fuel pump is selected on.
A