APU Flashcards

1
Q

T/F: The APU can be used during flight.

A

FALSE, Ground Only operation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

T/F: The APU can only be used on the ground.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

On which side of the fuselage is the APU air intake located?

A

Right rear side of the tailcone

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which of the following combinations causes the highest fuel burn while operating the APU?

A

Highest fuel burn is Generator ON and Bleed Air ON (270 lbs/hr)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When will the fuel shut off valve automatically close on the APU?

A
PWR switchlight pushed OFF
Airplane airborne
Fire detected in tailcone
EXTG (Extinguish) pushlight is pushed
APU fire test button is pushed
Starter-Generator overheats
APU fault is detected
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The APU is started with _____.

A

Main & Aux batteries
or
External power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Pressing the PWR switchlight on the APU control panel, in preparation for APU start, does which of the following?

A

Opens APU fuel shut off valve
Arms start circuits
Performs a brief self-test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

T/F: The APU cannot be used as a source of bleed air on the ground.

A

FALSE, it can be used as a bleed air source

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

T/F: APU bleed air can operate in conjunction with engine bleed air.

A

FALSE, it cannot be used in conjunction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

T/F: APU bleed air cannot operate in conjunction with engine bleed air.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

T/F: The APU can be used while the aircraft is airborne.

A

FALSE, the APU is limited to ground operations only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

T/F: The APU can be used on the ground for electrical, pneumatic, and hydraulic power.

A

FALSE, the APU does not provide hydraulic power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When ready to start the APU, what should be accomplished after pressing the PWR switchlight?

A

Verify green APU fuel valve open advisory light illuminates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The green ON light illuminates on the APU GEN switchlight when the APU is running at full speed and can supply which of the following?

A

28VDC power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where can the APU’s electrical load be monitored?

A

MFD electrical page

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

T/F: Once the APU is at normal operating speed, APU bleed air is automatically supplied with no pilot input.

A

FALSE, the APU BL AIR switchlight must be pressed and “OPEN” illuminated

17
Q

What color is the light that illuminates when the APU Fuel valve is OPEN?

A

Green advisory light on APU fire protection panel

18
Q

T/F: If the APU generator overheats, the APU will automatically shut down.

A

TRUE

19
Q

What will happen if an APU generator fault is detected?

A

Generator disconnected from DC electrical system,
ON light extinguishes from switchlight,
GEN WARN advisory light illuminates on switchlight

20
Q

Fuel for the APU operation is supplied from which fuel tank?

A

Left wing collector bay

21
Q

What does the APU GEN WARN light indicate?

A

Any of the following:
Generator has not been selected with the APU running
Generator is selected on but does not come on-line
Generator is taken off line due to a malfunction