APs Flashcards
DAILY STATION ROUTINE
OUTLINED DEPT. POLICY
IMPLEMENTED BY CAPT.
SHALL PARTICIPATE IN ALL PROGRAMS
ALL ENGINEERS
RESPONSIBILITIES
A CHECK B CHECK MAINT ON STATION AND PREMISES TRAINING PROJECT WORK PHYSICAL TRAINING
VEHICLE RESPONSIBILITY
CONDITION/MAINT APPARATUS AND CHIEFS VEH ASSIGNED
Daily inspection
FITTINGS, TOOLS, SUCTION HOSES, AND OTHER EQUIP.
WEEKLY CHECKS
Bolts, water lines, nuts and connections are tight
Wiring and working parts in proper condition
SIGNATURES REQ. BEFORE EXTENSIVE MAINT
ENGINEER, IMMEDIATE SUPERVISOR, BC, DEPT. FLEET MANAGER
DONE UNDER FLEET MANAGER DIRECT SUPERVISION
BRAKING SYSTEM
ELECTRICAL SYSTEM
STEERING SYSTEMS
PERFORMANCE APPRAISAL COMPLETED FOR NEW PROMOTED EMPLOYEES
TWICE DURING PROBATION
MID POINT AND NEAR COMPLETION
PPE MARKINGS
1 3/4” letters
BODY ARMOR MARKINGS
NO STENCIL OR MARKING IN ANYWAY ABOVE THE WAIST
ROUTINE CLEANING
DONE BY END USER WITHOUT OUT OF SERVICE
AFTER EACH USE
ADVANCED CLEANING
USE CLEANING AGENTS
TEMP OUT OF SERVICE
EXTRACTOR WASHER
ONCE EVERY 6 MONTHS
PPE USED AND SOILED SHALL BE CLEANED AND DOCUMENTED
SPECIALIZED CLEANING ALLOWED IN THE FIRE STATION
PRE SOAKING BIOHAZARD EXPOSED PPE IN CITRO D OR TB CIDE QUAT. EXTRACTORS
HYDROCARBONS
2 cycles in extractors
PRE SOAK IN ONE OUNCE ZEP POWERPLEX TO EACH GALLON
PPE EXPOSED TO BIOHAZARD
PRE SOAK IN BIOHAZARD BUCKET WITH ONE OUNCE OF CITRO D TO ONE GALLON OF WATER
DISINFECTS TAKES 10 MINUTES
MAX PEOPLE OFF ZONE 1
5 employees of any single rank, shift, maybe on combined leave at the same time.
MAX PEOPLE OFF ZONE 2
6 per shift, rank,
No scheduled combined leave dates
Thanksgiving, 12/24, 12/25, 12/31 without guarantee
Max trades per year
44
Less than 8 hour trade
May be approved by immediate supervisor
Not count as limited trade
BC AND ROSTER NOTIFIED
ADDITIONAL SHIFT TRADES (above 44)
ASSISTANT CHIEF CAN AUTHORIZE
STANDY PERSONNEL
EN ROUTE TO INCIDENT- 10 MINUTES
IN COUNTY ASSIGN WITHIN 1 HOUR
COMPANY INSPECTION OF EACH STATION
QUARTERLY BY BC
FITNESS PROGRAM
0830-1030
PERTINENT RECORDS MAINTAINED
3 YEARS
CLASS B DRIVERS LICENSE
CAPT 7/1/96 and after
DMV ENDORSE
ENGINES (TANK VEHICLES) N CREW TRANSPORT ( PASSENGER) P FUEL TENDER (TANK VEH W/HAZ MAT) X WATER TENDER TANK N LIGHT AND AIR X or H TANK 100 gal or more
DISTRICT NOTIFIED, IN 2 WEEKS, OF:
CITED OR CONVICTED OF DRIVING OFFENSE EVERY YEAR W/ NO CHANGES TO LICENSE LICENSE SUSPEND OR REVOKED INVOLVED IN ACCIDENT ANY ACTIONS TAKEN AGAINST DRIVERS PRIVILEGE
REVIEW OF LICENSE AND MEDICAL CARD
QUARTERLY
RECORD IN STATION JOURNAL
LIGHT/MODIFIED DUTY LIMIT
Nine months
TEMP ASSIGNMENT INTO VACANCY
MINIMUM 3 MONTH VACANCY
ALCOHOL 0.02% BUT BELOW 0.04%
REMAIN OFF EMERGENCY DUTIES FOR AT LEAST 8 HOURS.
NO LOSS OF PAY
ACCIDENT W/ INJURY, CITATION FROM ACCIDENT, PROPERTY DAMAGE EXCEEDS $5000
SUPT REFERS EMPLOYEE TO TESTING WITHIN 2 HOURS
SAFE SURRENDER KIT
CODED MEDICAL ID BRACELET
INFO SHEET
MEDICAL QUESTIONAIRE
-PLACED FIRST FILE IN FILED FORMS DRAWER.
APPARATUS WEIGHT MINIMUM
26,000 lbs.
Vehicle 9 ft. or taller
Shall have the vehicles height length width and weight recorded and visible to the driver operator
Backing guides
All apparatus and light fleet
Backing horn communication
Two signals forward
Three signals reverse
Uncontrolled railroad crossing
Pull to the right, stop, make sure the way is clear
Emergency water and food
Normal staffing levels for a period of seven days
Barrels shall be disinfected every 6 months
Gasoline engines oil weight
5w-30w or 5w-20w
Detroit diesel 60 series’s oil weight
15w-40
In-line six cylinder KME and ALF
Detroit diesel 92 series on Pierce engines oil weight
40w only
Mechanical emergency after working hours
F CC shall notify the heavy equipment mechanic on standby
Who may authorize individual apparatus modification
BUREAU CHIEF OF EMERGENCY SERVICES
INVENTORY MARKINGS
T-41
Light fleet may be marked with 4 digit county tag number
FIRE EXTINGUISHERS
HYDRO EVERY 5 OR WHEN NEEDED
CO2 NO HYDRO
UL LABEL MUST BE AFFIXED
County property over $200 and unserviceable
SPEED LETTER TO SUPPORT SECTION -BC
Unfit flags
Folded, labeled, -to Annex
MINOR EQUIP. THAT IS UNSERVICEABLE
DISPOSED OF WITH COMP OFFICER APPROVAL
FLAG FOR FIRST RUN (SPECIFIC DATES)
2’x3’
STANDARD FDC SET UP FOR SYST SIDE HYDRANTS
Four 2 1/2
HYDRANT MAINT
Flow tested -every 5 years
Flushed - every 3 years
By water company
BOT DOTS
6” from edge of centerline on hydrant side of center
Max number of sand bags
35