Air Systems Flashcards
On the ground an external air source can supply conditioned air directly into…
The left air conditioning manifold.
With the pack control selector in STBY-N the pack produces?
A constant moderate temperature (approx 75ºF/24ºC)
With the pack control selector in STBY-C the pack produces?
A full cold temp (65ºF/18ºC)
With the pack control selector in STBY-W the pack produces?
A full warm temp (85ºF/30ºC)
How are the ram air doors and the exhaust doors affected with the pack control selector in any STBY mode?
They sre fixed in the full open position.
The pack high flow system is automatic and is armed during normal opertation - T/F?
True.
If a pack overheat condition is detected, the respective pack cycles to..?
Max cooling.
If a pack fault condition is detected with the automatic pack control system, the respective pack valve will?
Remain in last controlled position.
A PACK OFF light indicates the pack valve is closed due to?
The selector is in the off position or a pack trip has occurred or loss of air to the pack.
INOP and a PACK OFF light can indicate?
An internal pack overheat.
Where is the overheat reset switch for a pack located?
In the INOP/PACK OFF light switch.
Conditioned air from the mix manifold is distributed to ______ temp controls zones on the B767-300P.
4
Which temp control zone does not have a temp indication on the B767-300?
FLT DK
Instead of a temp indication the FLT DK on the B767-300 has?
A valve position indicator.
Turning off the trim air switch will illuminate OFF in the switch and illuminate how many INOP lights on the B767-300?
4
If the selected automatic pressurization mode fails, what happens?
Alternate mode is automatically switched.
If automatic pressurization switching occurs during a mode failure, how is it displayed to the flight crew?
EICAS status msg.
What does AUTO INOP on the cabin altitude control panel mean?
Both auto controllers have failed, or manual mode has been selected.
What will the index mark on the cabin altitude auro rate control establish?
A climb of 500 FPM or descent of 300 FPM.
Where are the positive pressure relief valves located?
Left fuselage fwd of the wing.
When does the cabin Altitude Warning/Light illuiminate?
10,000’ Cabin Altitude.
The lower cargo area is divided into___ compartments?
3
Which cargo compartment/s utilize the center APU duct to supply warm air?
AFT and BULK
Where is the Bulk Cargo heat selector located?
Accessory panel.
The Bulk Cargo heat selector in vent position supplies warmer air and turns on a fan to improve circulation T/F?
True.
What is the function of the Bulk Cargo heat selector?
Allows a higher temperature to be selected for the Bulk compartment (Approx 65ºF)
The shoulder and foot heaters for each pilot only operate in flight T/F?
True.
When the aircraft is on the ground, circulation of cooling air for E/E components is normally produced by?
A supply and an exhaust fan.
A skin heat ex-changer is sometimes used to remove heat from the equipment cooling air and is controlled automatically, T/F?
True.
The valve light on the equipment cooling panel illuminates on the ground if?
One or more of the equipment cooling valves are not in the commanded position.