Air Systems Flashcards
-When does equipment cooling configure for flight?
-one or more engines on each wing are operating OR
-selecting STBY (manually)
On the ground, when is warm equipment cooling air ducted overboard?
-Engines not operating
-equipment cooling selector NORM
-ambient temperature moderate or high
Equipment cooling provides cooling air for what compartment and systems?
FD Equipment
Electrical and Electronic Equipment Racks (E&E)
What is the function of the lower lobe cargo air flow rate selector?
-Provides forward and aft cargo lobe conditioned air
On the -8 with main deck and FWD/AFT lower lobe temperature selector OFF, what is the temperature zone target?
20degrees Celsius
68 degrees Fahrenheit
On -8 What does the alternate ventilation system provide with pack 1,2&3 shutdown, and aircraft depressurized?
Outside air to the flight deck
On -8what position are main deck FWD & AFT temp selectors normally placed during preflight?
OFF
On -8 what position is the lower lobe aft cargo heat selector usually placed in during preflight?
LOW
The -8 ECS Left and Right trim air is provided to which temperature zones?
Left: FD/UD/CR/Aft Main Deck
Right: Fwd Main Deck/ FWD&AFT Lower Lobe
When in descent mode, will the cabin altitude controller program a slight positive or negative pressurization at touchdown?
A small positive pressurization at touchdown
How many cabin altitude controllers are provided?
Two A&B. Each controller controls both outflow valves
What does ZONE System (SYS) Fault light indicate?
-Temp zone duct overheat or zone temp controller fault
-Mater trim air valve failed closed
-Master trim air valve closed and pack air continues to flow
Under what conditions would High Pressure (HP) air be used?
-Descent
-Other low power setting operations
How would you isolate a bleed air duct section if a leak is detected?
*Follow the QRH
-Close respective isolation valve
-Close related engine bleed air valves
What does a bleed duct isolation (ISLN) valve light indicate?