Air Cond Flashcards

1
Q

ENG 1(2) BLEED (Normal) Bleed valve opens if….

A
  1. Upstream pressure is above 8 psi
  2. APU BLEED is OFF or APU VALVE is closed
  3. No leak, over pressure, or overtemp detected
  4. ENG FIRE pb has not been activated
  5. ENG start valve closed
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

An ENG 1(2) BLEED FAULT light means?

Will Fault light go out if fault no longer exsits?

A
  1. Over pressure
  2. Bleed air overheat
  3. Leak
  4. Not closed for ENG START
  5. Not closed with APU bleed ON

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The RAM AIR valve will open if pressed ON and?

A
  1. Ditching is in normal position
  2. Cabin diff press less than 1 psi
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

An APU BLEED FAULT light means?

A

APU leak detected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

An APU BLEED ON (Blue) light means?

A

APU VALVE IS OPEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When the X BLEED knob is selected SHUT it commands?

A

Crossbleed valve closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The X BLEED selector knob in AUTO will command the valve to open and close when?

A

Open if APU bleed is Open

Closed if APU bleed is Closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The X BLEED selector knob in OPEN commands?

A

Valve open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

PACK 1(2) pushed in and no FAULT light means the pack control is …..

A

Automatic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A PACK 1(2) FAULT light comes on with what 3 things?

A
  1. Pack control valve disagrees with selected position
  2. Compressor outlet overheat
  3. Pack outlet overheat
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When the HOT AIR light is not lit, it means the hot air pressure is regulated?

A

Automatically

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A HOT AIR FAULT light means?

Do the valves close automatically?

A

Duct overheat

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When HOT AIR is selected OFF, what valves close?

Will this reset the Fault?

A

The HOT AIR and TRIM AIR valves close.

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The ZONE TEMP selector range is….

A

64 to 86

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When the PACK FLOW selector knob is set to NORM the flow is?

A

Automatic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When the PACK FLOW selector knob is set to HIGH the pack flow =

When the PACK FLOW selector knob is set to LOW the pack flow =

HIGH flow is automatic with what 2 conditions?

A

HIGH = 120%

LOW = 80%

APU is being used or Single Pack