9 Master Stream Appliances Flashcards
During large fire incidents where should apparatus be located
Should be positioned so that radiant heat convected heat burning embers or structural collapse will not affect the safety of firefighters
When shouldn’t master stream appliances be placed in service defensively
While an offense of interior attack is being conducted
When our master stream appliances used
When handheld hose lines are ineffective they are used for fire attack exposure protection and back up
To be effective master streams require flows of what range
350 to 2000 gallons per minute
What are the three types of master stream appliances
Portable appliances, fixed appliances, elevated master streams
Portable master stream appliances are often referred to as
Deck guns or monitors
A portable master stream appliance moves were shifts from its position with might cause it
The nozzle is operating at too low of
Safety locks for nozzle angle must be manually released before the novel can you lower below what degree
35°
Which type of master stream appliance this placed on the ground and supplied with water from one or more hose line
A portable master stream appliance
Ariel pre-pipe water system on and Ariel with 110 feet or less in reach must be capable of flowing what
1000 gallons per minute at 100 psi nozzle pressure at full elevation and extension
Inlet size for an aerial waterway must be a minimum of what size
4 inch minimum inlet
The most common sizes of smooth for tips for master stream
1 3/8, 1 1/2, 1 3/4, 2 inch
Smooth bore master stream tips operate at what pressure
80 psi
An inch and three eights smooth for tip will flow how many gallons per minute
500 GPM
An inch and a half smooth for tip will follow how many GPM
600 GPM
The inch and three-quarter tip will flow how many GPM
800 GPM
The 2 inch tip will flow how many GPM
1000 GPM