7 Backup Lines Flashcards

1
Q

How are back up lines not to be used

A

Back up lines are not used for exposure coverage or to attack the fire that other positions.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When should a backup line be stretched

A

Whenever it is obvious that the fire will not be quickly extinguished with initial attack lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

True or false back up lines should be taken into the fire building immediately after the initial attack lines.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What type of line should be used as a backup line compared to the initial attack line

A

Back of lines should have greater reach and deliver more water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When 2 inch and three-quarter hose lines are used for initial attack what should the back up line be

A

2 1/2 inch hose line, It will flow almost the same as the 2 inch and three-quarter Lines and allow deeper penetration especially if used with a solid stream

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What size line should be used to back up a 2 1/2 inch initial attack line

A

Another 2 1/2 inch hose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If 2 inch and three-quarter winds are not effective adding three or four more would be ineffective just as much, what is needed that this doesn’t have

A

Reach, penetration, and cooling effect of larger hose lines

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If two or more inch and three-quarter attack lines are operating within one or two floors of each other which kind of hose would be sufficient to back them up

A

2 1/2 inch hose on the fire floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If a 2 1/2 inch hose is used for initial attack how should the back up line be configured

A

2 1/2 inch hose with larger smoothbore tips unless these are already in use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When the fire is so serious that the heaviest hose lines maybe used for the initial attack what must be available for backup

A

Master stream appliances

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The master stream appliance should be immediately placed into service and charged for back up so it can

A

The quickly placed in service to cover the escape of firefighters from dangerous positions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When an interior attack using 2 1/2 inch hose lines fail to control the fire what should happen

A

Back out all firefighters change to defensive attack using master stream appliances

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If back up lines need to be used what should be done with the initial attack lines

A

They should be shut down they have proven ineffective against the fire and can do a little in support the heavier streams

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

After back up lines have gained control of the fire and an advance can be made what can be done with the smaller of initial lines

A

They can be used to perform extinguishment and overhaul

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If 2 1/2 inch hose has been used for both initial attack in the back of wine what can be used for overhaul operations

A

An inch and three-quarter hose attached to the 2 1/2 inch nozzles or with wyes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Who should be assigned to deploy back up lines

A

They should not be given to firefighters who have already been engaged in initial attack operations additional fresh firefighters should be used

17
Q

Back up lines are needed when

A

Whenever it is obvious that the fire will not be quickly brought under control

18
Q

Back up lines should be staffed by

A

The company other than the company that is operating the initial attack mind

19
Q

What type of nozzle should be used on the back up lines

A

Smoothbore

20
Q

Back up line

A

And additional house line used to reinforce and protect personality any event the initial attack proves inadequate