737 Systems: Airplane General Flashcards

1
Q

Which color are used to indicate conditions that require immediate and timely attention of the flight crew?

A

Immediate: Red Warning Lights
Timely: Amber Caution Lights

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What causes the MASTER CAUTION and System Annunciator lights to illuminate?

A

They illuminate when ANY caution occurs OUTSIDE the normal field of vision of the flight crew

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How are Master Caution System indications different for a single channel fault than a dual channel fault?

A

When a single or simple fault occurs, the respective caution light, system annunciator, and MASTER CAUTION lights do not automatically illuminate. They are however stored in the Master Caution system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which flight deck windows open?

A

The number 2 windows. (Only the First Officers window can be opened from the outside)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Are there any speed limitations with the retractable landing lights?

A

There is no speed restriction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where are the WING lights located?

A

On each side of the fuselage to illuminate the leading edge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which systems can pressurize the Potable Water System? And what conditions must be met for the system to operate?

A

Bleed air from either the engines or APU or an electric air compressor.

The electric pump requires:
- Pressure in water tank less than 30 pasig (Pressure limit switch closed)
-Water service panel door is closed (compressor cut out switch is closed)
-CAB/UTIL switch is positioned ON

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When is 100% oxygen supplied to the flight deck oxygen masks?

A

When the Normal/100% switch is selected to 100%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How is the PASS OXYGEN system activated?

A

By an aneroid switch at a cabin altitude of 14000ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How long does PASS OXYGEN flow once the system is activated?

A

Approximately 12 minutes and cannot be shut off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What will cause the emergency exit lights to illuminate when armed?

A

-If electrical power to DC Bus 1 fails
Or
-If AC power has been removed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Can the Aft Attendant Panel EMERGENCY EXIT LIGHTS override the Flight Deck Control?

A

Yes it can

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What causes the emergency overwing exits to lock?

A

-A minimum of three of the four entry/service doors are closed
And
-Either engine is running
And
-The aircraft air/ground logic indicates that the aircraft is in the air or both thrust levers are advanced to the takeoff power position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly