3.2 "Power Distribution Limits" Flashcards
LCO 3.2.1 title
Linear Heat Rate
LCO 3.2.1 requirement
LHR shall be w/in limits specified in the COLR, and the Incore Alarm System or Excore Monitoring System shall be operable to monitor LHR
LCO 3.2.1 applicability
Mode 1 w/thermal power > 25%
LCO 3.2.1 required actions < 1 hour
LHR, as determined by the auto Incore Alarm System not w/in limits of the COLR, as indicated by 4 or more coincident incore channels, OR as determined by the Excore Monitoring System, OR as determined by manual incore detector readings
THEN restore LHR to w/in limits in 1 hour
LCO 3.2.2 title
Total Radial Peaking Factor
LCO 3.2.2 requirement
Total Radial Peaking Factor shall be w/in limits specified in the COLR
LCO 3.2.2 applicability
Mode 1 with thermal power > 25%
LCO 3.2.2 required actions < 1 hour
NONE
LCO 3.2.3 title
Quadrant Power Tilt
LCO 3.2.3 requirement
Quadrant Power Tilt shall be <= 0.05
LCO 3.2.3 applicability
Mode 1 with thermal power > 25%
LCO 3.2.3 required actions < 1 hour
NONE
LCO 3.2.4 title
Axial Shape Index
LCO 3.2.4 requirement
ASI shall be w/in limits specified in the COLR
LCO 3.2.4 applicability
Mode 1 with thermal power > 25%