2 - Air Systems Flashcards
Auto Altitude rates:
Min -
Max -
Auto Index -
50 fpm
2000 fpm
500 climb/300 descent
What systems use bleed air from the center duct?
ADP
Aft/Bulk cargo heat
Center hydraulic reservoir
What happens if Altitude Controller fails?
auto switches to other controller
What does Pressurization AUTO INOP light indicate? (3)
- both AUTO Controllers inop
- Outflow Valve stuck
- MAN selected
Equipment Cooling - NO COOLING
OVRD selected and no cooling air (inhibited for 1 min)
- 90 min before essential avionics and electrical equipment failures
Equipment cooling - OVHT
inhibited for 5 min after STBY selected
BLEED light
HP and/or PRV valves open when they should be closed
What is the purpose of the Trim Air system?
adds warm air to regulate zone temps
Temp Zone Control INOP light
One - (3)
All -
- duct overheat
- zone controller fault
- zone OFF
- trim air OFF (average 75F/24C)
Which zone controls pack output in AUTO?
zone requiring coolest temp
Pack INOP light
- auto controller fault
- can not be reset
- operate in STBY
N - moderate
C - cold (full)
W - warm (full)
Pack INOP and PACK OFF lights
- pack overheat (internal or output)
- pack auto to max cooling
- reset after pack cools