XTrap Fault Lights Flashcards
MAJOR FAULT
CB has tripped
23Q1&2
25,30,33, 36 in lead
25Q1 BCU in all MT
AUX FAULT
One or more SIVs not operating
Lost 1 SIV on 3 car - 1 HVAC, 1 air comp
Lost 2 SIV on 3 car - 400 vAC equip - 60 min battery
Fix - if no CB tripped attempt stable
AIR COMP FAULT
One or more not operating
Lose 1 - other takes over
Fix - Monitor MR
CB inaccessible to driver
If compressors not running attempt stable
SERVICE BRAKE FAULT
One or more faults in service brake
Possible Reduced brake performance
Fix - Trip/reset 25Q1 (prep)
Train set to 1 and release/ apply brake
Doesn’t fix - stable
TRACTION FAULT
Traction fault in this car
TCU will isolate fault
- no amps on gauge
- no traction on lead
Fix - stable
- MC to COAST and turn traction isolation switch to isolate
TWO HVAC STOPPED
Two stopped in one or more cars
No AC / ventilation
Fix - check HVAC switch on
- stable
MAJOR 2ND LEVEL FAULT
CB has tripped
Lead - 10Q1, 10Q2, 22Q11, 30Q2,
T Car - 10Q1, 22Q5, 21Q9.1, 21Q9.2,
M Car - 22Q6
BATTERY CHARGER FAULT
Battery charger not operating
60 mins of battery power
Emergency lights only
If lead unit no volt on meter
Fix - if no CB tripped attempt stable
LOW PRESSURE MR
Main Res pressure below 650kPa
Safety loop will open fall 580kPa
Safety loop will close rise 650kPa
Fix - monitor MR
- check for leak
- check air compressors
- isolate leak and manually release SPB
- safety loop bypass if req.
1 OR MORE BRAKE EQ FAULT
1 or more brake equip fault
Reduced brake performance
Possible NO service brake on one or more cars
Fix - Trip/reset 25Q1 (prep)
Train set to 1 and release/ apply brake
Doesn’t fix - stable
Still have ‘em. Brake
Will illuminate with service brake fault
1 OR MORE TRACTION EQ FAULT
Traction fault somewhere on train
TCU will isolate fault
Fix - stable
- if time permits check each M Car for traction fault light and isolate
ONE HVAC STOPPED
One HVAC stopped in one or more car
MINOR FAULT
CB has tripped
Applicable CBs inaccessible to driver
24 V CONVERT FAULT
One or more 110/24v converter not operating
Lose function of 24vDC equip.
If at least 1 converter working on 3 car unit, won’t lose equip.
LOW PRESSURE BP
Brake Pipe pressure below 430kPa
Safety loop open at 300kPa and close when rises to 430kPa
Traction available at 480kPa
Fix - check trainset in 2
CB inaccessible to driver
Safety loop bypass if required