utility rope stretch Flashcards
If encountering a bldg fire with stairs that wrap around an elevator a utility rope stretch via stair shaft window can be used to reduce number of lengths. What floor should fire be on to use this method?
3rd and above. If fire is below the 3rd floor (2nd), the line is stretched up the stairs.
What is the length and width of the utility rope used by engines for hose stretch?
75’ of 3/8” nylon rope
If utility rope stretch through staid shaft window who goes where?
Off proceeds to floor below fire with rope. Selects window and communicates this to control ff.
sufficient lengths brought into Lobby and folds placed near window. Nozzle ff attaches the rope to nozzle, and places nozzle outside window, then proceeds to floor below fire. The back up will join the nozzle ff when relieved by control man. Control remains there until enough line is pulled up. Once line is charged and links removed control joins nozzle team.