TB Apparatus P-3 Flashcards
When in line pumping ops are implemented , ____ hose shall be the initial supply line
3 1/2
What is the pump idle pressure ?
Lowest RPMS (55 psi in volume , 110 in pressure) plus hydrant pressure equals pump idle pressure Eg if hydrant pressure 50 psi then pump idle pressure in volume would be 105 psi
T or F
When charging the pump from a hydrant, insure all drains and inlets are in the closed position
True
Next, open the hydrant fully
When supplying water into any gated inlet , the inlet MUST be ____
Opened fully
Note: if going into a gated inlet , open the drain to the gated inlet to expel air PRIOR to opening the gated inlet
When residual pressure drops below ____ psi on the intake pressure gauge , augmentation will be required
15 Psi
1 3/4 hose with 1 5/16 nozzle = ___ psi at nozzle plus ___ psi per length friction loss
50 psi at nozzle and 20 psi per length
2 1/2 inch hose with 1 1/8 nozzle =
40 psi at nozzle plus 5 psi per length
Note: 5 psi for each floor above grade