Utility Emergencies Flashcards

1
Q

If any doubt concerning your ability to manage a incident involving gases or leaks request

A

HAZMAT Unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Methane has a vapor density of __ making it _____ than air

A

.55. Lighter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A note of caution is that natural gas in transmission pipelines and rail cars is _____ odorized, with ______

A

Not, Mercaptan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The flammable range for methane is _ % to __%

A

5% to 15%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ignition temperature for natural gas is about ______

A

1200 degreees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Markers show the pipeline’s approximate location

A

Not its exact location

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When shutting off the gas at the appliance, the shut off valve will be a quarter turn,

A

just prior to the regulator and appliance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

outside gas leaks and other outside gas emergencies, engine companies shall position the apparatus

A

prior to and upwind

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

general rule for apparatus positioning is no closer than ___
For the first arriving unit and a minimum distance of __

A

100 feet
300 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

During gas emergencies the second engine should stage at ____ outside the hot zone

A

The hydrant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Gas line over ___inches in diametershould be upgraded to an HAZMAT event

A

2 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

During a outside gas leak what is dispatched

A

1 engine
1 truck or rescue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Ensure who should be called enroute to a gas emergency

A

Gas Company

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If gas is leaking prior to a shut off and no gas is entering any structure the best course of action is

A

No action

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

fire department personnel shall ensure no persons enter a trench deeper than ___ that is not shored

A

5 Feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

To protect the utility company workers, units should position upwind with a ______ and a _____

A

20 LB dry chemical
Charged hose line

17
Q

All non-essential personnel, including firefighters and civilians, shall be kept out of the hot zone. The DOT Emergency Response Guide (ERG) suggests an evacuation distance ____

A

330 ft

18
Q

Gas lines are buried around ___ below the surface

A

24”

19
Q

Gas lines have a _____ _____ ____ over them for gas company can detect them.

A

Yellow coated wire

20
Q

If a gas line is on fire the best procedure is to _____

A

Protect exposures

21
Q

If a gas meter is on fire the best place to shut off is the ______

A

Curb valve

22
Q

Consideration must be given to a potential ignition source being an auxiliary generator. If the power to a structure is shut off at the electric panel this action may cause the generator to operat

A

Secure the generator prior to operating the electric panel.

23
Q

A gas regulator takes street pressure of up to __ psi and steps it down to somewhere of ___

A

40 psi
1/2 psi

24
Q

What are the two types of gas meters ____ and ____

A

Outside and inside

25
Q

All inside or enclosed gas installations are required to have the regulator vented to the outside via piping and must be within _ of the vent on an inside wall

A

5 feet

26
Q

When the gas meter is involved, and access to the meter shut off cannot be accessed, the best place to shut off the gas is at the

A

Curb

27
Q

Propane has an expansion ratio of

A

270:1

28
Q

Carbon Monoxide Emergencies dispatch

A

1 engine company
1 EMS unit

29
Q

Firefighters called to the scene of any CO alarm or smell of natural gas should dismount from the apparatus with full turnout gear and air packs in place. If the detection/monitoring equipment shows a reading of __ ppm should retreat from the structure and dawn SCBA

A

35

30
Q

Ground transformer
After power is removed it is recommended to extinguish any remaining fire with

A

dry chemical or CO2 extinguishers,