UNIT 8 : INDOOR ENVIRONMENTAL QUALITY Flashcards

You may prefer our related Brainscape-certified flashcards:
1
Q

_____ lobbies are considered regularly occupied because people often congregate,work on laptops, and spend more time there Than they do in an office building lobby.

A

Hotel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

For mechanically ventilated spaces, determine the minimum outdoor air intake flow for mechanical ventilation systems using the ventilation rate procedure from which standard?

A

ASHRAE 62.1–2010

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

For naturally ventilated spaces, an alarm must indicate when airflow values vary by ___ % or more from the exhaust airflow setpoint.

A

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

CO2 monitors must be between___ feet above the floor and within the thermal zone. CO2 monitors must
have an audible or visual indicator or alert the building automation system if the sensed CO2 concentration
exceeds the setpoint by more than ___

A

3 and 6, 10%.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

For help in determining whether natural ventilation is feasible for a building or space, see __________ Applications Manual

A

Chartered Institution of Building Services Engineers (CIBSE)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

_________ induce passive air movement from openings to the point of exhaust, requiring that airflow measurement devices be placed at the exhaust location.

A

Naturally ventilated systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

For prereq : Environmental Tobacco Smoke Control, prohibit smoking ___ the building

A

Inside

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Prohibit smoking outside the building and outside the property line in spaces used for business purposes, except _________ spaces

A

In designated smoking areas located at least 25 feet (7.5 meters) from all entries, outdoor air intakes, and operable windows.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

____ must be posted within 10 feet of all building entrances indicating the no-smoking policy.

A

Signage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

For prereq - Minimum acoustic performance : Achieve a maximum background noise level of ___ dBA from heating, ventilating, and air-conditioning (HVAC) systems in classrooms and other core learning spaces.

A

40

How well did you know this?
1
Not at all
2
3
4
5
Perfectly