What’s the TS Level for the FP Water Storage Tanks?
565,000 gal
What is the TS Level for the Diesel Driven Fire Pump Fuel Oil Storage Tanks?
160 gals for 8 hrs of Operation
What is the TS Level for the Condensate Storage Tank?
182,000 gals to maintain plant in hot standby for 9 hrs on PORVs with LOOP
What is the minimum pressure in the EDG Starting Air Receiver?
190#
What is the Minimum Level for the EDG Fuel Oil Storage Tank?
46,000 gal
What is the minimum level for the EDG Fuel Oil Day Tank?
101.4 gal
What is the temperature limit for lower containment?
60-120*F
What is the temperature limit for upper containment?
60-100*F
What is the T.S. Pressure Range for containment?
-1.5# to 0.3#
Plant Batteries are designed to last how long on LOOP?
3 hours
Plant Batteries are designed to last how long on a SBO?
4 hours
Degraded Bus Voltage is sensed on
2/3 on A and D T Busses at 113 Volts
Undervoltage is sensed on
2/3 on EACH T-Bus at 94 (93) Volts
The 17 ton CO2 Tank has a TS Limit of ____ #
285 #
What is the minimum Boron Concentration for the SFP?
2400 ppm
What is the REFUELING WATER STORAGE TANK min level? Why?
375,500 gallons min
for Recirc sump volume- 1 hr Spec
What is the REFUELING WATER STORAGE TANK Boron concentration? Why?
2400 to 2600 ppm boron- 8 hr Spec
Low end ensures subcriticality
High end for max time to HL recirc
What is the REFUELING WATER STORAGE TANK temperature range? Why?
70°F to 100°F- 8 hr spec
Low End Lower D/P rcs vs cntmt – backpressure
High End CTS to condense steam / 12#
What is the band for the volume for accumulators?
921 - 971 cuft
What is the pressure band accumulators?
585 - 658 #
What is the boron concentration for the accumulators?
2400 - 2600 ppm
Why is Hot Leg Recirc used?
Prevent boron plating