T-38 Operating Limits (Incomplete) Flashcards
EGT ºC
Ground Steady State
Start
*925 (Max)
845
EGT ºC
Ground Steady State
Military
630 - 650
EGT ºC
Ground Steady State
(Max) / Afterburner
630 - 650
EGT ºC
Flight Steady State
Start
*925 (Max)
EGT ºC
Flight Steady State
Military
630 - 650
EGT ºC
Flight Steady State
(Max) / Afterburner
630 - 650
EGT: *Abort start if EGT reaches ___ ºC to preclude exceeding temperature limits. Abort aircraft during ground start if EGT exceeds ___ ºC momentarily.
845 ºC
925 ºC
Total fluctuations in EGT of __ ºC (+/- __ ºC) are acceptable if the average EGT is between ____ ºC and ____ ºC.
15 ºC (+/- 7.5 ºC)
630 ºC and 650 ºC
What is the RPM for Ground Idle?
46 - 50%
What is the RPM for Ground Military?
99 - 101%
What is the RPM for Ground MAX?
99 - 101%
What is the RPM for Flight MIL?
99 - 104%
What is the RPM for Flight MAX?
99 - 104%
What is the fluctuation limit for RPM Ground Idle?
46 - 50%
What is the fluctuation for RPM Ground MIL/Max?
99 - 101%
What is the fluctuation for RPM Flight MIL and AB?
+/- 1%
Maximum allowable transient RPM is
107%
What is the Nozzle Position and Fluctuation Limit on the Ground at IDLE?
77 - 92% (None Allowed)
What is the Nozzle Position and Fluctuation Limit for MIL power?
0 - 20% +/- 3%
What is the Nozzle Position and Fluctuation Limit for MAX power?
50 - 85% (+/- 3%)
Following rapid throttle movements, nozzle position should stabilize within permissible fluctuation range within ___ seconds
10 seconds