Systems, Controls, Indicators, and Fault Lights Flashcards
Normal Law Protections
SLAP B
Speed (High)
Load Factor
Alpha (a prot, max, floor)
Pitch Attitude (+30 / -15)
Bank (15/sec rate 67 Left Right)
Alpha Prot
ASAP
AOA replaced load factor in pitch command
Speed brakes auto-stow / inhibited
Autopilot disengages
Pitch trim is inhibited in nose up direction
ELAC Functions
NADDAAA
Normal Elevator & Aileron, Pitch & Roll
Alternate Pitch
Direct Pitch
Direct Roll
Abnormal Attitude
Aileron Droop
Autopilot Commands
SEC Functions
SAD DAN
Speed Brakes / Spoilers
Alternate Pitch (Sec 1 & 2)
Direct Pitch (Sec 1&2)
Direct Roll
Abnormal Attitude
Normal Roll Via Spoilers
FAC Functions
YAWL
Yaw (Damping, Turn Coordination, Rudder Trim, Rudder Travel Limiting)
Airspeed Computations & Envelope
Windsheer Alerts
Low Energy Warning
Spoilers Inhibited
SAFET
Sec 1 & Sec 3 Failure
Alpha Prot or Alpha Floor
Flaps in Config Full (319/320) or Conf 3 (321)
Elevator Failure
TOGA Thrust
Wing Tip Brakes Engage
Runaway
Overspeed
Asymmetry
Movement Un-Commanded
ADR Computers in ADIRS
BOATS
Baro altitude
Overspeed warning
AoA
Temperature
Speed/mach
OR
AAATOM
Airspeed
Altitude
Alpha (AOA)
Temperature
Overspeed
Mach
IR Computers in ADIRS
FAAT HAG
FPV
Aircraft Position
Attitude
Track
Heading
Acceleration
Ground Speed
Engine Fire PB
Cancels CRC
Arms both Squibs
Hydraulic Fire SOV Closes
Fuel LP Valve Closes
Generator Deactivated (IDG)
Pack Flow Valve Closes
Engine Bleed Valve Closes
FADEC Power Removed
APU Fire PB
Cancels CRC
Arms Squib
Shuts Down APU
APU Fuel LP Valve Closes
APU Fuel Pump Shuts Off
APU Generator Deactivates
APU Bleed Valve Closes
Crossbleed Valve Closes
PTU Fault Light
OLL
Overheated Reservoir
Low Reservoir Fluid Quantity
Low Reservoir Air Pressure
Engine Hydraulic Pump Fault Light
(G or Y)
POLL
Pump Low Pressure
Overheated Reservoir
Low Reservoir Fluid Quantity
Low Reservoir Air Pressure
Electric Hydraulic Pump Fault Light
(B or Y)
POLLO
Pump Low Pressure
Overheated Reservoir
Low Reservoir Fluid Quantity
Low Reservoir Air Pressure
Overheated Pump
Fuel Pump Fault Light
Associated pump fuel delivery pressure is low
MODE SEL Fault Light
Center Fuel Tank has more than 550 lbs of fuel remaining and either Left or Right Wing Tank has less than 11,000 lbs of fuel remaining
Electrical System Priority
GEARB
Generator
External Power
APU
RAT
Batteries
BAT Fault Light
Charging current for battery outside limits, causes battery contractor to open
Engine or APU GEN Fault Light
GCU trip or Line contactor opens without GEN pb-sw Off
IDG Fault Light
HOT LOP
High Oil Temperature
Low Oil Pressure
AC ESS FEED Fault Light
AC Essential Bus is not powered (normally supplied by AC Bus 1, Alternatively AC Bus 2)
GALY and CAB / GALLEY Fault Light
The load on any generator is above 100% of its rated output
Pack Fault Light
PCP
Pack Outlet Overheat
Compressor outlet Overheat
Position Disagree with Pack Flow Valve
Engine Bleed Fault Light
LOOSA
Leak on associated Side (Wing or Pylon)
Overpressure
Overheat
Start Valve open and X Valve not closed
APU Bleed Valve Open and X Valve not closed
APU Bleed Fault Light
APU bleed air leak detected
Hot Air Fault Light
Duct overheat detected; Hot Air Valve and Trim Air Valved close automatically
Pack Flow Selector - When do you select low
Passenger Count Less Than
A319 is 138
A320 is 138+3 = 141
A321 is 138+ 30 = 168
When is the Pack automatically in high flow
When single pack operation or with air supplied by APU bleed
X Bleed Selector
Auto, Open, and Closed
Auto - Opens the crossbleed valve IF the APU bleed valve is open, closes the crossbleed valve if the APU bleed valve is closed (or if a bleed air leak is detected)
Open - Opens the crossbleed valve
Closed - Closes the crossbleed valve
Wing Fault Light (Anti-ice)
Valve position disagree with pb position
Low pressure detected
Eng Fault Light (Anti-ice)
Valve position disagree with pb position
Cabin Press Panel
MODE SEL Fault light
A fault detected in BOTH automatic cabin pressure controllers systems
DITCHING Push button Closes
OCRAP
Out flow valve (except in MAN press mode)
Cargo Isolation Valve
Ram Air Inlet
Avionics Inlet and Extract Valves
Pack Flow Control Valves
APU Master Fault Light
APU automatically shutdown
BLOWER Fault Light
CLSD
Computer Power Supply Failure
Low Pressure (Blower)
Smoke Warning Activated
Duct Overheat
EXTRACT Fault Light
CLS
Computer Power Supply Failure
Low Pressure (Blower)
Smoke Warning Activated
Hydraulics do what
Look at image
Cockpit door switch
Unlock, hold in position to allow door to be pushed open
Norm, latches locked and emergency crew access possible
Lock, door locked for preset time