STE #8 Flashcards

1
Q

Only HEPA and vacuum units with a current _____________test can be used to control airborne radioactivity

A

DOP/PAO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

All HEPA and vacuum units used inside the RCA must be tagged as internally contaminated and cannot be opened without Radiation Protection oversight. True or False?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Only those vacuum units labeled as ___________can be used to remove liquids

A

Wet vacuum or wet/dry vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If a vacuum unit has been used in an alpha level 2 it must be indicated as such on the radioactive tag. True or False?

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

All HEPA and vacuum units shall be DOP/PAO tested every __________.

A

24 months

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

HEPA units that require voltage greater than __________ requires maintenance support to connect the unit to the power source

A

120 V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is required to be installed on the suction end of the hose when the HEPA unit in being used to supporting grinding on contaminated pipe?

A

Spark arrestor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When not in service the following actions should be taken with HEPA and Vacuum units.

A
  1. Controlled in a manner that prevents their unauthorized removal and use.
  2. Have all opening covered and taped to prevent the spread of contamination,
    and 3. Have an “out of service” tag installed if the unit is not working properly.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

HEPA units can be used as an engineering control to reduce the need for respiratory protection equipment. True or False?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The potential for airborne activity being generated is evaluated using several factors including_________________.

A
  1. Work method being used (grinding, welding, ect)
  2. Available plant ventilation systems,
    and 3. Environmental conditions (wet/dry surface)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

______________ is the minimum air velocity required to overcome the motion of airborne particles or gases and accelerate them into the capturing airstream.

A

Capture velocity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

In cases where iodine is expected what should be included in the HEPA ventilation plan?

A

Add a charcoal filter unit to the system to remove the iodine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

It is important to implement contamination control measure prior to removal of the covers on the ends of the hoses to prevent the spread of contamination. True or False?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Prior to turning on a HEPA unit you should verify the following:

A
  1. The power cords are in good condition
  2. There is no physical damage to the unit,
    and 3. The DOP/PAO test has been completed within 24 months
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When routing HEPA ventilation hose it is important to

A
  1. Make straight runs and prevent bends to limit flow restrictions
  2. Keep hose in the overhead as much as possible to prevent trip hazards,
    and 3. Make sure the suction of the hose is close enough to the area where the airborne is expected to be generated to maintain the proper capture velocity.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

A __________ should be completed to prevent potentially dangerous vapors and fumes from being transported from one area of the plant to another in situations where these exist.

A

Safety Evaluation

17
Q

The survey frequency for a HEPA unit should be based on the potential for changing radiological conditions. The survey frequency for a unit should be listed on ________.

A

Attachment 4

18
Q

What actions can be taken to validate that a HEPA unit is functioning correctly?

A
  1. Install a continuous air monitor at the discharge of the unit.
  2. Collect air samples at the discharge of the HEPA unit.
    and 3. Smear the discharge of the HEPA unit
19
Q

Radworkers are allowed to open HEPA or vacuum units if they stop running while in use? True or False?

A

False

20
Q

Before storing a HEPA or vacuum unit in the plant it is important to consider…

A
  1. How easy it is to move the equipment from one location to another,
  2. Fire loading,
    and 3. The potential for spread of contamination