Only HEPA and vacuum units with a current _____________test can be used to control airborne radioactivity
DOP/PAO
All HEPA and vacuum units used inside the RCA must be tagged as internally contaminated and cannot be opened without Radiation Protection oversight. True or False?
True
Only those vacuum units labeled as ___________can be used to remove liquids
Wet vacuum or wet/dry vacuum
If a vacuum unit has been used in an alpha level 2 it must be indicated as such on the radioactive tag. True or False?
False
All HEPA and vacuum units shall be DOP/PAO tested every __________.
24 months
HEPA units that require voltage greater than __________ requires maintenance support to connect the unit to the power source
120 V
What is required to be installed on the suction end of the hose when the HEPA unit in being used to supporting grinding on contaminated pipe?
Spark arrestor
When not in service the following actions should be taken with HEPA and Vacuum units.
- Controlled in a manner that prevents their unauthorized removal and use.
- Have all opening covered and taped to prevent the spread of contamination,
and 3. Have an “out of service” tag installed if the unit is not working properly.
HEPA units can be used as an engineering control to reduce the need for respiratory protection equipment. True or False?
True
The potential for airborne activity being generated is evaluated using several factors including_________________.
- Work method being used (grinding, welding, ect)
- Available plant ventilation systems,
and 3. Environmental conditions (wet/dry surface)
______________ is the minimum air velocity required to overcome the motion of airborne particles or gases and accelerate them into the capturing airstream.
Capture velocity
In cases where iodine is expected what should be included in the HEPA ventilation plan?
Add a charcoal filter unit to the system to remove the iodine
It is important to implement contamination control measure prior to removal of the covers on the ends of the hoses to prevent the spread of contamination. True or False?
True
Prior to turning on a HEPA unit you should verify the following:
- The power cords are in good condition
- There is no physical damage to the unit,
and 3. The DOP/PAO test has been completed within 24 months
When routing HEPA ventilation hose it is important to
- Make straight runs and prevent bends to limit flow restrictions
- Keep hose in the overhead as much as possible to prevent trip hazards,
and 3. Make sure the suction of the hose is close enough to the area where the airborne is expected to be generated to maintain the proper capture velocity.