Which of the following is a requirement for entry into a High Radiation Area?
Dose rates in the area must be obtained and personnel made knowledgeable of them prior to entry.
When maintaining positive radiation protection control over activities inside a high radiation area an RP Technician should perform which of the following?
Perform periodic radiation surveillance, or surveys, of the area based on the RWP or site procedure requirements
To perform the requirement of maintaining positive radiation control over activities in a high radiation area and RP Technician must have a monitoring device, e.g. survey meter. True or False?
True
Which of the following individuals is allowed to sign out a key to an area posted as a Locked High Radiation Area?
An ANSI qualified SR Technician
In situations where a locked high radiation area has been found, and due to the physical configuration the area cannot be locked, flashing lights and a barrier maybe used to warn workers as long as it is allowed by which of the following?
Technical Specifications
If a Locked High Radiation Area has been un-locked and workers have entered the area, the door can only be locked while workers are inside, if workers can freely egress without the use of a key. True or False?
True
If a Locked High Radiation Area door is required to remain open what action must be taken?
Establish an Access Control Guard
What type of RP Coverage is required for a Locked High Radiation Area entry?
Continuous RP Coverage by ANSI qualified RP Technician
Every high radiation area is to be locked and entrance into the area is to be controlled by issuance of a key. True or False?
False
Individuals are required to have a brief prior to entry into a High Radiation Area or Locked High Radiation Area unless which of the following has occurred?
- Medical emergency has occurred,
- Fire alarm has occurred in the area,
- Event has occurred that could impact nuclear safety such as the loss of shutdown cooling
While performing a high radiation area briefing, and conflicts between the RWP requirements are identified, which of the following actions should be taken.
Suspend the briefing
Which of the following can be used to prevent items being stored in spent fuel pools from being raised to close to the surface.
- Interlocks on equipment can be installed to prevent their ability to raise the items.
and 2. Tie offs that are locked and controlled by Radiation Protection
The HRA/LHRA checklist is required to be completed for all high radiation entries. True or False?
False
A key can only be issued to a Locked High Radiation Area when which of the following condition(s) have been met.
- Key is issued only to RP personnel who are ANSI qualified,
and 2. Access has been authorized by an RP Supervisor or designee
Which of the following reason is acceptable for issuing a master key for Locked High Radiation Areas.
The RPM has approved the issuance to perform multiple door/barrier checks