STE #5 Flashcards

1
Q

Which of the following is a requirement for entry into a High Radiation Area?

A

Dose rates in the area must be obtained and personnel made knowledgeable of them prior to entry.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When maintaining positive radiation protection control over activities inside a high radiation area an RP Technician should perform which of the following?

A

Perform periodic radiation surveillance, or surveys, of the area based on the RWP or site procedure requirements

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

To perform the requirement of maintaining positive radiation control over activities in a high radiation area and RP Technician must have a monitoring device, e.g. survey meter. True or False?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which of the following individuals is allowed to sign out a key to an area posted as a Locked High Radiation Area?

A

An ANSI qualified SR Technician

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In situations where a locked high radiation area has been found, and due to the physical configuration the area cannot be locked, flashing lights and a barrier maybe used to warn workers as long as it is allowed by which of the following?

A

Technical Specifications

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If a Locked High Radiation Area has been un-locked and workers have entered the area, the door can only be locked while workers are inside, if workers can freely egress without the use of a key. True or False?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If a Locked High Radiation Area door is required to remain open what action must be taken?

A

Establish an Access Control Guard

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What type of RP Coverage is required for a Locked High Radiation Area entry?

A

Continuous RP Coverage by ANSI qualified RP Technician

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Every high radiation area is to be locked and entrance into the area is to be controlled by issuance of a key. True or False?

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Individuals are required to have a brief prior to entry into a High Radiation Area or Locked High Radiation Area unless which of the following has occurred?

A
  1. Medical emergency has occurred,
  2. Fire alarm has occurred in the area,
  3. Event has occurred that could impact nuclear safety such as the loss of shutdown cooling
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

While performing a high radiation area briefing, and conflicts between the RWP requirements are identified, which of the following actions should be taken.

A

Suspend the briefing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which of the following can be used to prevent items being stored in spent fuel pools from being raised to close to the surface.

A
  1. Interlocks on equipment can be installed to prevent their ability to raise the items.
    and 2. Tie offs that are locked and controlled by Radiation Protection
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The HRA/LHRA checklist is required to be completed for all high radiation entries. True or False?

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A key can only be issued to a Locked High Radiation Area when which of the following condition(s) have been met.

A
  1. Key is issued only to RP personnel who are ANSI qualified,
    and 2. Access has been authorized by an RP Supervisor or designee
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which of the following reason is acceptable for issuing a master key for Locked High Radiation Areas.

A

The RPM has approved the issuance to perform multiple door/barrier checks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The Operations Shift Manager has the authority to issue a master key for Locked High Radiation Areas in a situation where fire alarms are occurring in the plant. True or False?

A

True

17
Q

Maintaining control of keys to Locked High Radiation Areas is critical. Which of the following helps to ensure positive control is maintained

A
  1. Inventory of keys on a daily bases,
  2. Formal checkout and return process,
    and 3. Locking the key cabinet and maintaining it under positive control
18
Q

Keys issues for a Locked High Radiation Area, with the exception of master keys, should only unlock the area for which the key was issued. True or False?

A

True

19
Q

Before you can transfer a Locked High Radiation Area key to another individual, which of the following must be verified.

A

Individual receiving the key is an ANSI qualified RP Technician and has been briefed.

20
Q

You are the RP Technician providing job coverage for entry into a Locked High Radiation Area. Upon completion of the work, and as you exit the area, you cannot get the door to lock. What action should you take?

A

Maintain positive control over the entrance and notify RP Supervision for assistance.

21
Q

The purpose of a Peer Check when securing a Locked High Radiation Area is to provide additional verification that the door is locked and secured to prevent unauthorized access. True or False?

A

True

22
Q

Which of the following items should be discussed during a high radiation area briefing

A
  1. Expected dose rates for the area to be entered,

and 2. Validate the dosimetry requirements are adequate