Stall Warning System Flashcards

1
Q

If the L or R STALL WARNING caution light illuminates, what may have failed?

A

DC power failure
Lift tranducer failure
Lift computer failure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If the L or R STALL WARNING caution light illuminates, what else would you expect to see?

A

Speed control pointer on EADIs removed from display and a red X appear over the display

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The L and R stall Warning has electrically independent sub systems. What are the components of these sub systems?

A
Lift computer
Vane type lift tranducer
Column shaker
Speed control indicator
Caution light
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The L and R stall Warning systems use come common components/inputs. What are they?

A

Test switch
Heater switch
Flap indicator system
PSEU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How does the stick shaker work?

A

The lift tranducers transmit AoA info to their lift computers. The computers combine this info with flap position and internally generated accelerometer inputs to arrive at a stall speed threshold. The computers activate the stick shakers if the threshold speed is reached.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How does the 1.3vs indicator work

A

Similar to Stick shaker. The stall computer gets into from the lift tranducers, internal accelerometer and flap position to. The info is provided to the EADI to be displayed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In a 300 series, there are 2 independent stall Warning/stick pusher computers. What are their inputs?

A
AHRS
ADC
Flap position
Engine torque
De ice system
Raw AoA
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When do the stick pusher and stick shaker activate?

A

Stick shaker activates when the AoA reaches the computers stall Warning reference
Stick pusher when the AoA reaches the reference stick pusher AoA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

In a 300, what happens if an AoA sensor fails?

A

It’s associated STALL SYST FAIL and PUSHER SYS FAIL caution lights illuminate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How does stick pusher activation occur

A

When both computers agree the AoA exceeds the reference AoA a pneumatic actuator system uses nitrogen to apply a push force to the pilots elevator control quadrant.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly