CTS details for HP side door dispatch on SC8/GQ6?
- Dims?
- Weights?
- Min density?
- Min Drop Ht (Agl)?
- L25” x W15” x H45”
- SC/GQ6 30 - 85 Kgs (Ex Chute)
- 5 Kg/Cu Ft
- 250 ft AGL
CTS details for HP ramp dispatch?
- Dims?
- Chutes and weights?
- Min density?
- Min Drop Ht (Agl)?
- L48” x W30” x H45”
- SC/GQ6 30 - 90 Kgs O/L 113 Kgs (Ex Chute)28ft 70 - 160 Kgs O/L 230 Kgs (Ex Chute)2 x 28ft 160 - -320 Kgs No O/L (Ex Chute)
- 5 Kg/Cu Ft
- 250 ft AGL (400 ft for 2 x 28ft)
CTS details for SEAC Pack ramp dispatch?
- Dims?
- Chutes and weights?
- Min density?
- Min Drop Ht (Agl)?
- L32” x W18” x H13”
- SC/GQ6 30 - 85 Kgs (Ex Chute)28ft 70 - 85 Kgs (Ex Chute)
- 5 Kg/Cu Ft
- 250 ft AGL
CTS details for Jungle Line side door dispatch?
- Dims?
- Chutes and weights?
- Min density?
- Min Drop Ht (Agl)?
- L25” x W15” x H24”
- SC/GQ6 70 - 85 Kgs (Ex Chute)
- 9 Kg/Cu Ft
- 600 ft AGL
CTS details for Jungle Line ramp dispatch?
- Dims?
- Chutes and weights?
- Min density?
- Min Drop Ht (Agl)?
- L36” x W25” x H24”
- SC/GQ6 70 - 90 Kgs O/L 113 Kgs (Ex Chute)28ft 90 - 113 Kgs (Ex Chute)
- 9 Kg/Cu Ft
- 600 ft AGL
CTS details for Steel Barrel ramp dispatch?
- Dims?
- Chutes and weights?
- Min density?
- Min Drop Ht (Agl)?
- L36” x Diameter 23”
- 28ft 160 - 180 Kgs O/L 230 Kgs (Ex Chute)2 x 28ft 180 - 320 Kgs No O/L (Ex Chute)
- 9 Kg/Cu Ft
- 500 ft AGL
CTS details for Ski Pack (Canadian Tube) dispatch?
- Dims?
- Chutes and weights?
- Min density?
- Min Drop Ht (Agl)?
- L86” x 28” Diameter
- 2 x 28ft 160 - 320 Kgs No O/L (Ex Chute)
- 5 Kg/Cu Ft
- 400 ft AGL
CTS details for Large Oversill Load (LOSL) dispatch?
- Dims?
- Chutes and weights?
- Min density?
- Min Drop Ht (Agl)?
- L48” x W48”x H50” (45” Min)
- 2 x 28ft 230 - 320 Kgs No O/L (Ex Chute)
- 5 Kg/Cu Ft
- 400 ft AGL
CTS limitations for maximum size and mass for Light Stores despatch from PTD?
- Max Mass?
- Max Length?
- Max Width?
- 85 Kgs (Ex Chute)
- 25”
- 15”
What additional procedure must be followed for simultaneous despatch of Jungle Lines from the PTDs?
A 2 second delay is mandated between the left and right PTD.
Where must despatch crew members stationed on the forward position of the PTD attach their harness?
To a TDP level or forward of FR51.
Where must parachutes attached to TDPs be weak linked?
At the parachute apex (unmodified).
Where must Jungle Line static lines be attached?
To a TDP.
Which is the only role Large Light Stores (LOSL/Ski Pack) can be despatched using??
Role 1 due to being the only one with an end stop placed at the end of the Inboard Starboard Cable to initiate a modified parachute static line.
State the Light Stores Hang Up Drill?
“LOAD EMERGENCY HANG UP PORT/STBD/RAMP” - ALM
Evaluate then state whether the Hang Up is endangering the aircraft - ALM
If hang up is endangering the aircraft;
PF - “CUT FREE THE HANG UP”
ALM - Cut free and call “LOAD GONE”
PM - Mark Position at Load Gone
If hang up is stable and NOT endangering the aircraft
RED LIGHT - ON
If hang up is from PTD:
PM - Yaw trim apply 50% toward the hang up side
Avoid habitation, Gentle turns toward the hang up side, maintain drop speed, enter the Race Track, Push HUD Tac PB, Re-program the original CARP, Re-fly the CARP, at drop height.
At GREEN LIGHT - “GREEN ON, CUT FREE”
PM - Press Yaw Trim Reset
“Hang Up Drill - Complete”
After Drop Checklist - Action