Scenarios Flashcards

1
Q

The C90 is having battery issues and wont turn ON?
The instructor has tried restarting the control loading program.

A
  • Three steps to follow and reverse (six in total)
    Complete a motion cabinet power recycle.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The C90 FMS is not working properly in the C90.
All simulators were shut down last night because of storms.

A

Perform an AIC and I/O master-slave module reboot:
- Test the FMS for functionality
Reseed the avionics module in the flight cabinet
- Test the FMS for functionality

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When calibrating the B206 “Control Loading” will not calibrate, says it fails. What to do?

A

System > Tools > Launch Controller > STOP
Press START when prompted (illuminated green)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Control Loading isn’t working in the 412 CPT after a night where the system was completely shut down. What would you do?

A

There are multiple failure points are possible
> Loss of data communication between CLM server and the DAS/Cube.
> Firewire problem in Moog’s associated card.
> Firewire communication failure in Das’ associated card

Check quick list of eCLMnt faults excel spreadsheet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

CPT “IOS”? is having problems; has completely froze on two instructor screens.

Scenario: The crew have a scenario loaded and you can do one of two things.

A
  • Don’t interrupt the scenario that is already loaded
  • Restart the avionics module. Cycle it ON/OFF
  • Restart the server that is frozen
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

FMS was not working properly on the C90

A
  • Press to turn OFF the avionics chassis power
  • Press to turn OFF slave and master I/O power buttons
  • Wait 30 seconds to 1 minute?
  • (Did not work after powering back ON)
  • Reseeded the avionics module in the flight cabinet
  • Turn ON the FMS and check for functionality
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

There’s an instrument glitch in the C90/412S&CPT simulator program and the simulator software is stuck?

A
  • Press to turn OFF the AIC (Avionics Interface Computer) chassis DC power
  • Press to turn OFF slave and master I/O DC power
    buttons
  • Wait 30 seconds to 1 minute?
  • (Did not work after powering back ON)
  • Reseeded the avionics module in the flight cabinet
  • Turn ON the FMS and check for functionality
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

G5 simulator visuals are crashing on its own

A
  • Click administration
  • click shutdown system
  • Power ON all servers after shutdown
  • Open diagnostics (Service Desk)
  • Check DMS connection
  • Go into DMS program
  • Click Job: no tasks
  • Run Self-Test?
  • Click Tools
  • Turn Lamps ON

Additional Trouble shooting:
- Parts swap: Encoder, Potentiometer, Tension Adjustment

  • Could be the bios in the server
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

One of the projector screens is not functioning in any Simulator

A
  • Click administration
  • click shutdown system
  • Power ON all servers after shutdown
  • Open diagnostics (Service Desk)
  • Check DMS connection
  • Go into DMS program
  • Click Job: no taks
  • Run Self-Test?
  • Click Tools
  • Turn Lamps ON
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The simulator was turned OFF the evening prior and the batteries won’t turn ON in the C90?

A
  • Restart the F/D IO.
  • Check for fuses that may be popped.
  • ## Check for errors in the logs.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Control Loading needs to be Reset in the G5?

Scenario: Control loading has tripped because the pilot pushed the controls while the sim was loading

A
  • Open Computer
  • Press 2
  • Enter login name and password 0000
  • Enter login and password on screen dv1
  • FOLLOW RCA. Reset commands
  • Test control loading function on screen
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The batteries in the G5 won’t work, no functionality

A
  • Miscellaneous computer was not ON. Selection one on the control loading computer and then F2 for start up. Windows + D? Soft restart on IOS computer. This worked.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly