SCBA/Fast-Pak/Pak-Tracker Flashcards
Because the facepiece does not cover the ears, airborne contaminants can enter the respiratory tract through a ___ or ___ eardrum
Punctured or ruptured
A confined space is defined as any area that is not designed for ___ human occupancy. Large enough so a person can ___ and ___. Has limited means for ___ and ___
Continuous
Enter and Work
Entry and Escape
The SCBA cylinder holds ___ breathing air
Purified
The service life of a cylinder is ___ years
15
Hydrostatic testing is done every ___ years. 10 minute escape cylinders used by SOC units for confined space need to be hydrostatic tested every ___ years
5
3
Inspect all spare cylinders (depots, high-rise units, company and reserve apparatus) weekly on ___ for FULL pressure
Mondays
Designated training cylinders are designated with a ___ top and/or a ___ protective sleeve
blue
polymer
Consisting of two systems the PRA normally reduces the operating pressure to ___ psi before entering the regulators low pressure hose
100 psi
The regulator then controls the pressure within the face piece to slightly ___ atmospheric pressure
Above
A malfunction of the PRA’s primary system will automatically direct breathing air into a secondary system. When this occurs, the operating pressure will only be reduced to ___ psi and the vibralert alarm to activate. Member must notify their officer and immediately leave the contaminated area accompanied to a safe area by another member using an SCBA.
150
Failure of both the primary and secondary systems in the open position will activate a relief valve in the PRA, which will rapidly discharge all pressure in excess of ___ psi into the atmosphere. When this occurs the cylinder valve should be ___ ___ allowing only a minimal amount of air to release, permitting the member to both breath and conserve air. The member must notify their officer and immediately leave the contaminated area accompanied to a safe area by another member using an SCBA
185
Partially closed
If the manual shut-off fails to release for any reason, turn the red purge valve ___, ___ degrees to start the flow of air
Downward
180 degrees
If failure of the regulator in the open position (too much air flow in the face-piece), air-flow can be controlled by opening the purge valve ___ and ___ closing the cylinder valve.
Fully
Partially
The vibralert and HUD work ___ and may not activate at precisely the same time.
Independently
Will the vibralert alarm for malfunction of the PRA’s primary system?
Yes