Emergency Procedures Flashcards

1
Q

The MSA Altair Digital gas meter is equipped with two sensors, what are they?

A

Combustible gas and Oxygen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The Altair digital gas meter is calibrated to detect what component of natural gas? Can it be used to detect other gases?

A

Methane and yes but we are not to use it to monitor for other gasses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

While air monitoring the Altair digital gas meter will emit a vibrating pulse and flashing green LED light every _____ to alert the user that the meter is operating.

A

30 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In fresh air, the normal sensor readings on the Altair digital gas meter LCD screen should read LEL ___ and O2___

A

LEL 0.0%

O2 20.8%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The Altair digital gas meter will alarm at the following LCD readings
LEL-
O2 enriched-
O2 deficient-

A

LEL- 10.0%
O2 enriched- 23.5%
O2 deficient- 19.5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Can a defective MSA Altair digital gas meter ever be sent through the bag?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Can a unit put identifying markings on the MSA Altair digital gas meter?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When using the MSA Altair digital gas meter what is the indoor action level and what is the outdoor action level? As these levels are approached, ventilation procedures should be initiated.

A

Indoor- 10% LEL

Outdoor- 20% LEL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A series of what will display under the COMB/EX icon on the Altair digital gas meter when the atmosphere is above 100% LEL? This is an extremely dangerous atmosphere as it is indicative of a potentially explosive environment that members should not operate in except for life saving purposes

A

XXX

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The low oxygen level alarm is set at what percentage on the Altair digital gas meter? Upon activation of the oxygen sensor , members shall don their SCBA facepiece and notify the IC

A

19.5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The high oxygen sensor on the Altair digital gas meter will alarm at what percentage?

A

23.5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When the atmosphere is above 30% oxygen what will appear on the screen below the O2 icon on the Altair digital gas meter? This is an extremely dangerous condition.

A

+++ (plus signs)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly