SCBA Flashcards

1
Q

Scott Pak Alert SE-7 Battery Test

A
  • Lithium Batteries - used by FDNY
  • Automatic (green light flashing, no sound) = 2000 hrs
    • Alkaline = 1000 hrs
  • Full Alarm = 8-16 hours
    • Alkaline = approx 8 hours
  • Full alarm - audible tone - CAN EXCEED 95 DECIBELS @
    APPROX 10’
  • Battery test - Press & hold reset button on console (when Pak
    alert SE-7 is OFF)
    • Green light = Sufficient battery power
    • Red Light = Must replace b4 use SCBA again
    • Low Battery = Steady chirp EVERY 2 SECONDS W/NO
      FLASHING LIGHTS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

SCBA I.D.

A
Eng  -  Black
Lad. -  Red
Rescue - Blue
HM - Blue
Squad - Yellow
BN. -  YELLOW
BN SPARE - ORANGE
Marine - Green
MSU SPARE - Black
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In event M CANNOT ACHIEVE GOOD SEAL W/ANY FACEPIECE

4.2.3.E

A
  • Inhale for seal; Reposition & try again; Other M
  • IF STILL NO SEAL:
    • Safety Cmd & MSU IMMED. NTFY’D BY TEL
    • Rpt fwd’d by Co. Cmdr. To Bur. of Ops.
      - Bur. of Ops. Fwd’s Rpt to Safety Cmd
    • M NOT TO OPERATE IN AREAS REQUIRING SCBA
      USAGE UNTIL PROBLEM RESOLVED
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Facepiece sizes / Facepiece Seal Colors

3.9.1

A

Comfort Seal = Black color face seal

Sm. = Green color face seal

XL = Red color face seal

** NO LARGE!!
“The GREENS are SMALL; BLACK Label is the STANDARD (COMFORT SEAL); RED XL”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

H.U.D. = Heads Up Display

2 Green Lights

3.8.9

A

Rectangular

FULL CYLINDER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

H.U.D. = Heads Up Display

1 Green Light

3.8.9

A

Rectangular

3/4 FULL CYLINDER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

H.U.D. = Heads Up Display

1 Yellow Light

3.8.9

A

Rectangular

FLASHING SLOWLY ONCE PER SECOND

1/2 FULL CYLINDER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

H.U.D. = Heads Up Display

1 Red Light

3.8.9

A

Rectangular

FLASHING RAPIDLY 10x PER SECOND

1/4 FULL CYLINDER = LEAVE HAZ. AREA IMMED.
- M MUST NTFY THEIR OFF. & IMMED. LEAVE CONTAM’D
AREA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

H.U.D. = Heads Up Display

1 ROUND Red Light

3.8.9

A
  • @ Far right of HUD = Los Battery
  • Will log for 20 seconds & then flash SLOWLY @ ONCE PER
    SECOND
    • BATTERIES STILL HAVE SUFFICIENT LIFE TO OPERATE
      HUD LONGER THAN LONGEST DURATION CYLINDER
      INSTALLED IN SCBA (Low Batter = DON’T HAVE TO
      EXIT!)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

All of FDNY SCBA’s have….

1.2

A

HUD
UAC
CBRN approval

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

CBRN approval means that SCBA’s has met NIOSH & NFPA criteria for exposure to _____ agents.

1.2

A

Liquid Mustard AND Sarin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

An approved SCBA CBRN regulator can be ID’d by its _____. An approved back frame assy. can be ID’d by its _____.

1.2

A

Orange background label;

CDC NIOSH sticker

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Cylinder pressurized to _____.

3.2.2

A

4500 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Service life of an air cylinder is _____.

3.2.3

A

15 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Hydrostatic testing of cylinders done every _____.

3.2.4

A

5 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

10 minute escape cylinders used by SOC hydrostatic tested every …..

3.2.4.A

A

3 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

EOSTI alarms (vibralert & HUD) actuate when _____ of full cyl pressure remains in the cyl & valve assy.

3.2.8

A

25%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

If SCBA used in a pressurized tunnel or caisson at 2 atmospheres, the duration will be _____ as long as when used at 1 atmosphere. And at 3 atmospheres, will be _____ as long.

3.2.9

A

1/2;

1/3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Inspect all spare Cyl’s (depots, HRU’s, Co. & reserve apparatus) when??

3.2.12

A

Weekly on Mondays for FULL psi (4500)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Designated Trng Cyl’s are ID’d with a _____.

3.2.15

A

Blue top &/or a polymer sleeve.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Each _____ has been issued a _____ which includes a mannequin outfitted in condemned bunker gear and a mask harness for Trng purposes.

3.2.16

A

Bn;

Emergency Removal Trng Kit

22
Q

PRA normally reduces operating pressure to _____ before entering the regulator’s low pressure hose. The regulator then controls pressure within Facepiece to _____.

3.6.1

A

100 psi;

Slightly above atmospheric

23
Q

Malfunction of PRA’s primary system =. Operating pressure will only be reduced to _____ and cause vibralert to activate.

3.6.2

24
Q

Failure of both primary AND secondary systems IN OPEN POSITION will activate a relief valve in PRA, which will rapidly discharge all pressure in excess of _____ into the atmosphere. When this occurs….

3.6.3

A

185 psi;

The cyl valve should be partially closed, allowing only a minimal amount of air to release, permitting M to both breathe & conserve air.

25
If the manual shutoff switch mounted on top of e regulator assy is NOT pressed, a full 45 minute cyl can be depleted in _____. 3.8.2.A
Approx. 4 minutes
26
How is purge valve used? Failure of the regulator in the _____ position (no air to Facepiece) = _____? 3.8.4.B.6
CLOSED; Turn purge valve counterclockwise
27
How is purge valve used? Failure of the regulator in the _____ position (too much air flow in the Facepiece) = _____? 3.8.4.B.6
OPEN; Air flow controlled by opening purge valve fully AND PARTIALLY CLOSING CYL VALVE
28
_____ have been issued small AND XL facepieces to be used as spares for units under their Cmd. Unites requiring a spare small or XL Facepiece shall ctc their _____. 3.9.2.A
DIVISIONS; DIVISION
29
Components of the nosecp assy (Inhalation valves, voicemitters, voicemitter ducts & nosecp retainer) help remove _____ from within the Facepiece. 3.9.5
Carbon Dioxide
30
If Scott Pak-Alert sensor module does not sense motion of SCBA for _____ = Pre-alarm. If still no motion for next _____ = Full alarm. 3.10.5 4. 2.9.H ~ During Insp., SCBA must be moved or turned every _____ to prevent he sounding of the full alarm. 7. 5 ~ When a PASS alarm is activated in full cycle for _____, the M hearing the alarm should IMMED NTFY the IC.
20 seconds; 12 seconds; 30 seconds or less; 10 seconds
31
Full Alarm condition includes an audible tone that can exceed _____ decibels at _____ ft. 4.2.9.C
95; 10
32
When donning Facepiece, loosen helmet chinstrap so there is just enough to grab with a GLOVED hand, approx. _____. 5.4.1
1"
33
Contaminated SCBA's or components that can't be cleaned or disinfected due to blood or other body fluids shall: 8.3
- Be placed in dbl sealed clear plastic bag with biohazard label attached. - Tag attached to bag noting details of Incident including known and suspected contaminants - Placed on rig in approp. Loc & transported back to qtrs. - AQ, bag placed in light traffic area - NTFY SOC for p/u * When Devon, bagging or handling such equip. to be sent to SOC, M's shall wea BSI!!
34
Regulator disinfecting ~ Spray a MINIMUM OF _____ FULL PUMPS (70% Isopropyl Alcohol from a Spray Bottle) into the regulator opening. Allow for _____ of contact time to disinfect prior to rinsing. 8.6.5
6; 10 Minutes ** ALCOHOL & WATER SHOULD NOT BE DIRECTED INTO SPRAY BAR PORTS.
35
Each Bn is assigned _____ spare SCBA's. An RT-2 stating "ANNUAL PMP" should be attached & fwd'd with spares to MSU on the following schedule: 9.1.4
``` 12; January 1 = Spares 1, 2, 3 April 1 = Spares 4, 5, 6 July 1 = Spares 7, 8, 9 October 1 = Spares 10, 11, 12 ```
36
BORO & DIV assigned SCBA's are fwd'd _____. 9.1.5
APRIL 1
37
Bn ASSIGNED SCBA'S are fwd'd _____. 9.1.6
AUGUST 1
38
SCBA status RPT completed _____ by each _____. RPT is due _____. 9.2.1
ANNUALLY; Unit Cmdr; November 1st
39
SCBA color code Engine 10.3
Black
40
SCBA color code Ladder 10.3
Red
41
SCBA color code Rescue 10.3
Blue
42
SCBA color code HAZ Mat 10.3
Blue
43
SCBA color code Squad 10.3
Yellow
44
SCBA color code Battalion 10.3
Yellow
45
SCBA color code Bn Spare 10.3
Orange
46
SCBA color code Marine 10.3
Green
47
SCBA color code MSU Spare 10.3
Black e.g. MS-1
48
Add. 4 - EDSCBA (ED = Extended Duration) Up to _____ of breathable air 1.3
4 hours 6. 1.3 ~ OP. PLAN SHALL NOT EXCEED 3 Hours, 30 Minutes * EDSCBA NOT FOR ROUTINE STRUC. FF'ing OR UNDERWATER OPS.
49
Add. 4 - EDSCBA He following units have been trained in the use of EDSCBA's 1.5
``` Rescue Co's Squad Co's HMC1 HMTU Eng's Rescue & HM BN's * SELECT SSL Co's * SELECT BN's ```
50
Add. 4 - EDSCBA For penetrations _____ from the safe entry point, SOC units can deploy Supplied Air Respirators fed by hose lines from an Airsource Cart. 1.4 Note
LESS THAN 300'