SCBA Flashcards
Scott Pak Alert SE-7 Battery Test
- Lithium Batteries - used by FDNY
- Automatic (green light flashing, no sound) = 2000 hrs
- Alkaline = 1000 hrs
- Full Alarm = 8-16 hours
- Alkaline = approx 8 hours
- Full alarm - audible tone - CAN EXCEED 95 DECIBELS @
APPROX 10’ - Battery test - Press & hold reset button on console (when Pak
alert SE-7 is OFF)- Green light = Sufficient battery power
- Red Light = Must replace b4 use SCBA again
- Low Battery = Steady chirp EVERY 2 SECONDS W/NO
FLASHING LIGHTS
SCBA I.D.
Eng - Black Lad. - Red Rescue - Blue HM - Blue Squad - Yellow BN. - YELLOW BN SPARE - ORANGE Marine - Green MSU SPARE - Black
In event M CANNOT ACHIEVE GOOD SEAL W/ANY FACEPIECE
4.2.3.E
- Inhale for seal; Reposition & try again; Other M
- IF STILL NO SEAL:
- Safety Cmd & MSU IMMED. NTFY’D BY TEL
- Rpt fwd’d by Co. Cmdr. To Bur. of Ops.
- Bur. of Ops. Fwd’s Rpt to Safety Cmd - M NOT TO OPERATE IN AREAS REQUIRING SCBA
USAGE UNTIL PROBLEM RESOLVED
Facepiece sizes / Facepiece Seal Colors
3.9.1
Comfort Seal = Black color face seal
Sm. = Green color face seal
XL = Red color face seal
** NO LARGE!!
“The GREENS are SMALL; BLACK Label is the STANDARD (COMFORT SEAL); RED XL”
H.U.D. = Heads Up Display
2 Green Lights
3.8.9
Rectangular
FULL CYLINDER
H.U.D. = Heads Up Display
1 Green Light
3.8.9
Rectangular
3/4 FULL CYLINDER
H.U.D. = Heads Up Display
1 Yellow Light
3.8.9
Rectangular
FLASHING SLOWLY ONCE PER SECOND
1/2 FULL CYLINDER
H.U.D. = Heads Up Display
1 Red Light
3.8.9
Rectangular
FLASHING RAPIDLY 10x PER SECOND
1/4 FULL CYLINDER = LEAVE HAZ. AREA IMMED.
- M MUST NTFY THEIR OFF. & IMMED. LEAVE CONTAM’D
AREA
H.U.D. = Heads Up Display
1 ROUND Red Light
3.8.9
- @ Far right of HUD = Los Battery
- Will log for 20 seconds & then flash SLOWLY @ ONCE PER
SECOND- BATTERIES STILL HAVE SUFFICIENT LIFE TO OPERATE
HUD LONGER THAN LONGEST DURATION CYLINDER
INSTALLED IN SCBA (Low Batter = DON’T HAVE TO
EXIT!)
- BATTERIES STILL HAVE SUFFICIENT LIFE TO OPERATE
All of FDNY SCBA’s have….
1.2
HUD
UAC
CBRN approval
CBRN approval means that SCBA’s has met NIOSH & NFPA criteria for exposure to _____ agents.
1.2
Liquid Mustard AND Sarin
An approved SCBA CBRN regulator can be ID’d by its _____. An approved back frame assy. can be ID’d by its _____.
1.2
Orange background label;
CDC NIOSH sticker
Cylinder pressurized to _____.
3.2.2
4500 psi
Service life of an air cylinder is _____.
3.2.3
15 years
Hydrostatic testing of cylinders done every _____.
3.2.4
5 years
10 minute escape cylinders used by SOC hydrostatic tested every …..
3.2.4.A
3 years
EOSTI alarms (vibralert & HUD) actuate when _____ of full cyl pressure remains in the cyl & valve assy.
3.2.8
25%
If SCBA used in a pressurized tunnel or caisson at 2 atmospheres, the duration will be _____ as long as when used at 1 atmosphere. And at 3 atmospheres, will be _____ as long.
3.2.9
1/2;
1/3
Inspect all spare Cyl’s (depots, HRU’s, Co. & reserve apparatus) when??
3.2.12
Weekly on Mondays for FULL psi (4500)
Designated Trng Cyl’s are ID’d with a _____.
3.2.15
Blue top &/or a polymer sleeve.
Each _____ has been issued a _____ which includes a mannequin outfitted in condemned bunker gear and a mask harness for Trng purposes.
3.2.16
Bn;
Emergency Removal Trng Kit
PRA normally reduces operating pressure to _____ before entering the regulator’s low pressure hose. The regulator then controls pressure within Facepiece to _____.
3.6.1
100 psi;
Slightly above atmospheric
Malfunction of PRA’s primary system =. Operating pressure will only be reduced to _____ and cause vibralert to activate.
3.6.2
150 psi
Failure of both primary AND secondary systems IN OPEN POSITION will activate a relief valve in PRA, which will rapidly discharge all pressure in excess of _____ into the atmosphere. When this occurs….
3.6.3
185 psi;
The cyl valve should be partially closed, allowing only a minimal amount of air to release, permitting M to both breathe & conserve air.
If the manual shutoff switch mounted on top of e regulator assy is NOT pressed, a full 45 minute cyl can be depleted in _____.
3.8.2.A
Approx. 4 minutes
How is purge valve used?
Failure of the regulator in the _____ position (no air to Facepiece) = _____?
3.8.4.B.6
CLOSED;
Turn purge valve counterclockwise
How is purge valve used?
Failure of the regulator in the _____ position (too much air flow in the Facepiece) = _____?
3.8.4.B.6
OPEN;
Air flow controlled by opening purge valve fully AND PARTIALLY CLOSING CYL VALVE
_____ have been issued small AND XL facepieces to be used as spares for units under their Cmd. Unites requiring a spare small or XL Facepiece shall ctc their _____.
3.9.2.A
DIVISIONS; DIVISION
Components of the nosecp assy (Inhalation valves, voicemitters, voicemitter ducts & nosecp retainer) help remove _____ from within the Facepiece.
3.9.5
Carbon Dioxide
If Scott Pak-Alert sensor module does not sense motion of SCBA for _____ = Pre-alarm. If still no motion for next _____ = Full alarm. 3.10.5
- 2.9.H ~ During Insp., SCBA must be moved or turned every _____ to prevent he sounding of the full alarm.
- 5 ~ When a PASS alarm is activated in full cycle for _____, the M hearing the alarm should IMMED NTFY the IC.
20 seconds; 12 seconds;
30 seconds or less;
10 seconds
Full Alarm condition includes an audible tone that can exceed _____ decibels at _____ ft.
4.2.9.C
95; 10
When donning Facepiece, loosen helmet chinstrap so there is just enough to grab with a GLOVED hand, approx. _____.
5.4.1
1”
Contaminated SCBA’s or components that can’t be cleaned or disinfected due to blood or other body fluids shall:
8.3
- Be placed in dbl sealed clear plastic bag with biohazard label attached.
- Tag attached to bag noting details of Incident including known and suspected contaminants
- Placed on rig in approp. Loc & transported back to qtrs.
- AQ, bag placed in light traffic area
- NTFY SOC for p/u
- When Devon, bagging or handling such equip. to be sent to SOC, M’s shall wea BSI!!
Regulator disinfecting ~ Spray a MINIMUM OF _____ FULL PUMPS (70% Isopropyl Alcohol from a Spray Bottle) into the regulator opening. Allow for _____ of contact time to disinfect prior to rinsing.
8.6.5
6;
10 Minutes
** ALCOHOL & WATER SHOULD NOT BE DIRECTED INTO SPRAY BAR PORTS.
Each Bn is assigned _____ spare SCBA’s. An RT-2 stating “ANNUAL PMP” should be attached & fwd’d with spares to MSU on the following schedule:
9.1.4
12; January 1 = Spares 1, 2, 3 April 1 = Spares 4, 5, 6 July 1 = Spares 7, 8, 9 October 1 = Spares 10, 11, 12
BORO & DIV assigned SCBA’s are fwd’d _____.
9.1.5
APRIL 1
Bn ASSIGNED SCBA’S are fwd’d _____.
9.1.6
AUGUST 1
SCBA status RPT completed _____ by each _____. RPT is due _____.
9.2.1
ANNUALLY;
Unit Cmdr;
November 1st
SCBA color code
Engine
10.3
Black
SCBA color code
Ladder
10.3
Red
SCBA color code
Rescue
10.3
Blue
SCBA color code
HAZ Mat
10.3
Blue
SCBA color code
Squad
10.3
Yellow
SCBA color code
Battalion
10.3
Yellow
SCBA color code
Bn Spare
10.3
Orange
SCBA color code
Marine
10.3
Green
SCBA color code
MSU Spare
10.3
Black
e.g. MS-1
Add. 4 - EDSCBA (ED = Extended Duration)
Up to _____ of breathable air
1.3
4 hours
- 1.3 ~ OP. PLAN SHALL NOT EXCEED 3 Hours, 30 Minutes
* EDSCBA NOT FOR ROUTINE STRUC. FF’ing OR UNDERWATER OPS.
Add. 4 - EDSCBA
He following units have been trained in the use of EDSCBA’s
1.5
Rescue Co's Squad Co's HMC1 HMTU Eng's Rescue & HM BN's * SELECT SSL Co's * SELECT BN's
Add. 4 - EDSCBA
For penetrations _____ from the safe entry point, SOC units can deploy Supplied Air Respirators fed by hose lines from an Airsource Cart.
1.4 Note
LESS THAN 300’