Emergencies 1 - Elevator Ops. Flashcards
Fireman Service Regs
5.1
3 OR MORE LANDINGS OR TRAVEL 25’ OR MORE (if plans filed after Jan. 1, 1980)
ALL CLASS E BLDGS (w/plans filed subject to Local Law 5)
Group E BLDGS deemed “Existing” under local law 5 IF 100’ OR MORE IN HEIGHT
Group E Bldgs., 100’ Or More in Height:
of Elev’s w/F.S.
5.1
Fl. Serviced by 3 OR LESS = EVERY CAR
Fl. Serviced by MORE THAN 3 = 3 w/Total 6000 lbs
* 1-2 cars for ALL FL’S AND 1 OTHER CAR IN OTHER BANK
FOR THAT FL.
Total = < 6000 lbs. = EVERY CAR!!
When Elev. car reaches its terminal floor, one of the following will occur:
5.3.1.D.6
All car AND HW doors open 8 secs. - 1 Min. & then close OR
All Car/HW doors open;
- FS Elev's. Open w/Lites on - Non-FS Elev's close btwn 8 secs. - 1 Min. OR
All Car/HW doors Open & remain open;
- FS Elev Lites On & Non-FS Lites go Off