ROOF Flashcards

1
Q

HRFPMD
1st roof brings what ?
Goes

A

Halligan
Hydra Ram
KO CURTAIN

Apt Above via ATTACK STAIR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

HRFPMD

2nd roof brings what

A

Halligan
Maul
LSR / Life Belt
Apt Above via ATTACK STAIR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

HRFPMD

3rd Roof brings

A

KO Curtain and Normal Tools

Apt Above via ATTACK STAIR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

LWFPMD

1st Roof

A

Halligan Hook
Halligan
LSR / Belt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

LWFPMD
2nd Roof

TOP FLOOR FIRE ?

A

Halligan Hook
Halligan
LSR / Belt

TAKES KO CURTAIN IN LIEU OF LSR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

LWFPMD

ROOF ACCESS

A

Roof Access will be obtained using the following priority order:

  1. Stairway in an attached adjoining building. In an individual building with two separate sections protected by fire doors, the use of a protected adjoining section is the priority. In this situation, these doors must be checked on the fire floor and the floors above to ensure that they are in the closed position.
  2. An enclosed evacuation stairway.
  3. Aerial Ladder or Tower Ladder.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

LWFPMD

Roof Access ISOLATED BUILDING ONE OPEN INTERIOR STAIRWAY and roof can not be accessed aerial TL

A

a decision must be made by the company officer.
If the stairway is NOT AN IDLH and safety permits, the Roof Firefighter may be ordered to take the interior stair to the roof, provided that the fire apartment door is controlled and maintained closed by the ladder company officer.
If the stairway is an IDLH, then the Roof Firefighter must be teamed up with another member

In either case, the fire apartment door must be maintained closed until the Roof Firefighter has communicated to their Officer that they are on the roof in a safe area, and that the bulkhead door is closed. If ordered by the IC, provide ventilation of the stairway bulkhead. The Roof Firefighter will remain on the roof until the fire is under control and the interior stairway is safe to descend.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

CLASS 2

1st Roof

A

Halligan
Maul/axe
Hydra RAM

NO LSR NO CURTAIN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

CLASS 2

2nd ROOF

A

Halligan
Halligan Hook
LSR / Belt

DROPS LSR OFF FLOOR ABOVE

IF FIRE WITHIN 2 floors Roof take LSR to the ROOF

note: 2nd due office will ensure KO to roof for TOP FLOOR FIRE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

BROWNSTONE
2nd Roof

Top Floor ?

A

Halligan
6’ Halligan Hook

6’ Halligan Hook
SAW

the roof firefighter of the 2nd ladder company
may raise and use their aerial as a means of access to the roof

For fire below the top floor, be alert to first arriving roof firefighter’s request for
a saw

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Brownstone
1st Roof
TOOLS:
Access

A

Halligan Tool
6’ Halligan Hook
Life Saving Rope (LSR)
Aerial, 2nd Aerial, Adjoining

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

High rise Nozzle

A

inspected weekly
tech services
200-225 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

3.2.6 Roof Position
TOOLS:
Access

A

Halligan tool
6`Halligan Hook
Life Saving Rope

Adjoining
Aerial
Rear FE ( least desirable)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Peaked Roof PD
Roof Access
TAP

A

ROOF ACCESS (Order of Preference)
Tower Ladder
Aerial Ladder
Portable Ladder

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When possible, the preferred position of the apparatus at a Peaked roof PD is

A

parallel to the front of building, so the basket can be placed over the corner of the building near the peak of the roof. The TURNTABLE should be positioned to enable the basket to cover two sides.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Peaked Roof PD

If the apparatus cannot be placed in the preferred position, place the basket to the ?

A

If the apparatus cannot be placed in the preferred position, place the basket to the “valley” area where a hook ladder can be used to reach the peak

17
Q

Access FLAT Roof PD

A

Access to the roof via aerial, tower ladder or portable ladders, dependent upon topography and other conditions (wires, trees etc.).

18
Q

Another option for roof access flat PD

Use of an attached exposure for interior access to the roof depends

A

another option is to take the scissor ladder to a similar uninvolved attached exposure top floor to gain access to the roof via the scuttle.

the type of building construction. In attached wood frame type P.D.’s the immediate adjoining building should not be used due to the possibility of cockloft involvement.

19
Q

For attached P.D.’s of ordinary brick construction where firewalls exist between buildings, choose the building offering the easiest access to its interior.

A

true

20
Q

LowRise
If the 1st Roof Firefighter determines a LSR operation is not practical from the roof level, then the following options are available: who brings the LSR when there are two enclosed stairs ?

A

The 2nd Roof Firefighter shall bring their assigned tools including the LSR to the apartment directly above the fire apartment

In buildings with two enclosed stairs, the 2nd Roof Firefighter may descend the evacuation stairway to the apartment directly above the fire apartment.

21
Q

LowRise
If the 1st Roof Firefighter determines a LSR operation is not practical from the roof level, then the following options are available: who brings the LSR when there is one open stair ?

A