Random Flashcards
atmosphere is PROVEN non-hazardous via continuous meter readings.
Safe Atmospheric Conditions
1. Oxygen Concentration between?
2. Flammable Range - Not over ?
3. Toxicity - Not over ? PPM of Carbon Monoxide
4. Toxicity - Not over ? PPM of Hydrogen Sulfide
- Oxygen Concentration between 19.5% and 23.5%
- Flammable Range - Not over 10% of LEL
- Toxicity - Not over 35 PPM of Carbon Monoxide
- Toxicity - Not over 10 PPM of Hydrogen Sulfide
ow many turns to shut off street hydrant
Counter clockwise 17 turns
after about 12 turns noticeable diff
!8 turns to turn on yellow hydrant clockwise
Rowframe
An engine company ordered to an exposure for cockloft extinguishment should take what ?
A 6’ HOOK
The following system of touch signals can be used in conjunction with verbal commands to relay orders: • Opening or closing the nozzle- • Direction of stream-- • Advancement of hoseline-- • Halt or stop advance-
-One or two slaps on the back or shoulder.
Tug or pull on the arm or nozzle, either left or right.
Steady push on back or mask cylinder.
-Pull back on shoulder, bunker coat or mask assembly.
A physical communication system between the Guide Man and the Operator will be as follows: A. One slap on the back of Operator B. Two slaps on the back of Operator C. Three slaps on the back of Operator
……………Stop Cut.
………….Cut.
………..Shut Down Saw.
In Line Pumping The following signals shall be sent from back step buzzer: One buzzer tone Two buzzer tones Three buzzer tones
———–Emergency stop.
———-Hose FF is in position, pumper to proceed.
——–Area to rear of pumper is clear for backing up operations and under proper supervision.
This starter enable switch must be depressed while the chauffeur starts the engine. After the engine has been started, the foot pedal is
released. The steering wheel horn can be used as the
starter enable switch and
buzzer.
Regarding the use of this Tiller FF signal buzzer, the following sequences of signals is recommended:
- One (1) buzzer tone signal
- Two (2) buzzer tone signals
- Three (3) buzzer tone signals
– STOP
– Tiller FF in position to respond.
– Area to rear of apparatus clear for back up operations when properly supervised by officer and guides
buzzer should be checked each tour