If you get an external failure on a RMS, what happens?
High Alarm Auto Actions
What are the RMS Channels?
PILAMHP - 248
1 - Particulate 3 - Iodine 5 - Low Range Noble Gas 6 - Area 7- Medium Noble Gas 9 - High Range Noble Gas 10 - Process Flow
Minus Channels 2, 4 and 8
What kind of monitors are R-5 / VRS-5005 (5006)?
LR Noble Gas
What happens if R-5 / VRS-5005(5006) Aux Fuel Handling area rad monitors gets a high alarm?
AFS Fan Trips
Puts AFX fan in charcoal mode
What kind of monitors are R-17 A/B and CRS-3301/3401 (CRS-4301/4401)?
CCW Particulate
What closes CRV-412, CCW Surge Tank Vent Valve?
High alarm or loss of sample flow on
R-17A/B
U1 CRS-3301/3401
U2 CRS-4301/4401
What happens on a High Rad signal on R-19?
B/D DCRs close
B/D Sample DCRs close
DRV-350 closes
What happens on a high rad on R-24?
Closes B/D DCRs
Closes B/D Sample DCRs
Closes DRV-350
Trips B/D Treatment Pump
What kind of monitor is RRS-1001?
Liquid Effluent Particulate or Flow
What happens on a high rad on RRS-1001?
12-RRV-285 closes
Monitor Tank Pumps Trip
WECT Pumps Trip
Which rad monitors alarming could be indicative of a SGTR?
1800 (2800) / 1900 (2900)
SJAE & GLSO
What happens on a Train A high rad on upper / lower containment radiation monitors?
Closes VCR-101 - 107, inside containment valves
Trips CIPS Fan
What happens if you get a high rad on Train B Upper / Lower Containment Rad Monitors?
VCR-201-207 closes (outside containment valves)
Trips CPS Fans
Trips CPX Fan
Trips CPR Fan
Trips CIPX Fan
What does a high rad on the LR Noble Gas Vent effluent RMS do? (1505)
closes 1-RRV-306
What does a high rad on HR noble gas vent effluent RMS do? (1509)
closes VRV-318, Opens VRV-317 and redirects flow