Misc Signals Flashcards

1
Q

What will a High Rad signal cause in the SFP Area? (R-5)

A
  1. Aux Fuel Supply Fans Trip

2. Aux Fuel Exhaust Fans go into Charcoal Filter Mode.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Will the AES Fan automatically go into Charcoal Filter Mode on a High Rad Signal?

A

No. It must be done manually. (Auto on phase B)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A high rad signal on which rad monitors will start the Control Room Pressurization Fans?

A

Unit 1 7401

Unit 2 8401

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What will close the CCW Surge Tank Vent Valve?

A

High Rad on:
R17A/B
CRS-3301 and 3401
CRS-4301 and 4401

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What will happen on a High Rad on R-19?

A
  1. DRV-350 Closes
  2. SG BD Isolates
  3. BD Sample Valves Close
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What will happen on a High Rad on R-24?

A
  1. DRV-350 Closes
  2. SG BD Isolates
  3. BD Sample Valves Close
  4. BD Treatment Pump Trips
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What gives a Feed Water Isolation Signal?

A
  1. SG Hi-Hi 67% 2/3 on 1 SG
  2. Rx Trip (P-4) with Low Tave 554*F
  3. SI
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What happens on a FWI Signal?

A
  1. FRVs Close

2. FMOs Close

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What gives a Steam Line Isolation Signal?

A
  1. Hi-Hi Containment Pressure of 2.8 #s on 2/4
  2. Low Steam Line Pressure < 500 #s on 1/1 on 2/4 SGs
  3. Hi Steam Flow with P-12
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens to Containment Ventilation on a Load Conservation Signal?

A

Several Fans Trip

  1. CPR Fans
  2. Upper Ctmt Vent Fans
  3. IR Vent Fan
  4. PZR Enclosure Fan
  5. Hot Sleeve Vent Fan
  6. Rx Cavity Supply Fans
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How does the CRP realign on High Rad?

A

Damper 1, normal outside air closes

Damper 2, alt outside air part opens

Damper 3, Recirc stays open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

An autostart of what gives an AFW flow conservation signal?

A

MDAFW pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the purpose of an AFW flow conservation signal?

A

Conserves inventory and max flow to the SGs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the purpose of an AFW flow retention signal?

A

protects against runout (over-rides conservation signal)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What enables AMSAC?

A

C-20: Turbine 1st stage > 40% (2/2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are the Time Delays for AMSAC?

A

based on power from 40% - 100%, 220 sec - 27 sec

17
Q

What gives you a CVI?

A
  1. Ctmt Activity High

2. SI

18
Q

What gives you a Turbine Trip?

A
  1. SI

2. SG Hi-Hi 67% 2/3 on 1 SG

19
Q

What gives you a Reactor Trip?

A
  1. Turbine Trip
  2. SI
  3. Non-Safety Bus Undervoltage
  4. SG Level Lo-Lo