Misc Signals Flashcards
What will a High Rad signal cause in the SFP Area? (R-5)
- Aux Fuel Supply Fans Trip
2. Aux Fuel Exhaust Fans go into Charcoal Filter Mode.
Will the AES Fan automatically go into Charcoal Filter Mode on a High Rad Signal?
No. It must be done manually. (Auto on phase B)
A high rad signal on which rad monitors will start the Control Room Pressurization Fans?
Unit 1 7401
Unit 2 8401
What will close the CCW Surge Tank Vent Valve?
High Rad on:
R17A/B
CRS-3301 and 3401
CRS-4301 and 4401
What will happen on a High Rad on R-19?
- DRV-350 Closes
- SG BD Isolates
- BD Sample Valves Close
What will happen on a High Rad on R-24?
- DRV-350 Closes
- SG BD Isolates
- BD Sample Valves Close
- BD Treatment Pump Trips
What gives a Feed Water Isolation Signal?
- SG Hi-Hi 67% 2/3 on 1 SG
- Rx Trip (P-4) with Low Tave 554*F
- SI
What happens on a FWI Signal?
- FRVs Close
2. FMOs Close
What gives a Steam Line Isolation Signal?
- Hi-Hi Containment Pressure of 2.8 #s on 2/4
- Low Steam Line Pressure < 500 #s on 1/1 on 2/4 SGs
- Hi Steam Flow with P-12
What happens to Containment Ventilation on a Load Conservation Signal?
Several Fans Trip
- CPR Fans
- Upper Ctmt Vent Fans
- IR Vent Fan
- PZR Enclosure Fan
- Hot Sleeve Vent Fan
- Rx Cavity Supply Fans
How does the CRP realign on High Rad?
Damper 1, normal outside air closes
Damper 2, alt outside air part opens
Damper 3, Recirc stays open
An autostart of what gives an AFW flow conservation signal?
MDAFW pump
What is the purpose of an AFW flow conservation signal?
Conserves inventory and max flow to the SGs
What is the purpose of an AFW flow retention signal?
protects against runout (over-rides conservation signal)
What enables AMSAC?
C-20: Turbine 1st stage > 40% (2/2)