RHR Flashcards

1
Q

Purpose of RHR

A
  • Removes residual heat from reactor core and the RCS during plant cooldowns
  • Transfers water from the RWST to the reactor cavity prior to refueling operations. (Fast fill)
  • Transfers water from the refueling cavity back tot he RWST after a refueling operation.
  • Supports CVC system operations (forced letdown)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

RHR pumps take suction from?

A
  • The RWST for a borated water source during an accident.
  • The CV sump to recirculate and cool spilled water after an accident
  • RCS lop 2, Hot leg for normal core cooling
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

RHR pumps discharge to?

A
  • All 3 RCS loops cold legs
  • Back to the SI and CV spray pump suctions
  • Alternate to SI pump B&C suctions
  • To the CVC system (HCV-142)
  • Recirc back to the RHR pump suctions
  • RWST
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

RHR pump suction valves
RHR-752A/B
power and locations
precaution?

A
  • MCC-5 A
  • MCC-6 B
  • In RHR pump room
  • Must be manually moved on its closed seat prior to opening the valves
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

RHR pumps
Sump pump
power supplies
Seal cooling?

A
  • RHR pump A -E1/MCC-1 for sump pump
  • RHR pump B-E2/MCC-2 for sump pump
  • Seal cooling provided by CCW
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

RHR pump room cooling

A

-HVH-8A and 8B
-8A is in Bravo pump bay
-8B is in Alpha pump bay
If one is out of service, associated Pump is also inoperable. Cooled by Service water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

RHR Hx cooled by?

A

-CCW on shell side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

RH-744A/B RHR loop discharge to RCS isolation valves.

How does it open?

A

-SI signal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Core Cooling and Startup RHR-750 and 751 (RHR pump suction from loop2 hot leg)
powered by? concerned with?

A
  • Powered by
  • 750-MCC-5
  • 751-MCC-6
  • Smart fire concern
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

During startup or cooldown, RHR-750 and 751 can only be opened when RCS pressure is? and?

From RC Loop 2 Hotleg

A
  • <445psig and SI-862A/B are closed, with power and SI-863A/B are closed, with power,(no power they are sensed as open.)
  • Protects downstream RHR
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

RHR loop temperature control with FCV-605 and HCV-758

A

-FCV-605 keeps steady flow, Moving HCV-758 increases or decreases flow through RHR Hx thus increasing or decreasing temp but not flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly