Reviewer 1 Flashcards
As per PD 1185, what is the minimum number of exits for Class A places of assembly with a capacity of more than 1,000 persons?
- 4
What is referred to in works to building/ structures involving changes in the materials used, partitioning, location/ size of openings, structural parts, existing utilities and equipment but does not increase the building height and/ or floor area?
- Alteration
As per PD 1096, what is the minimum clearance between the established grade of a street and/ or sidewalk and the lowest understructure of any part of a projecting balcony?
- 3.00 m
As per BP 344, how much is the parking slot width for handicapped drivers and passengers providing sufficient clear space between parked cars to allow them to transfer to a wheel chair?
- 3.7 meters
What is the minimum lot frontage for row house units in economic housing as provided for in BP 220?
- 3.5 meters
As per PD 1096, what is the minimum clear ceiling height for mezzanine floors above and below it?
1.80m
As per BP 344, how long is the extension of handrails which shall be provided from the start and end of ramps and stairs?
- 300 mm.
As per PD 1096, what is the ratio of parking slot to number of units in residential hotels and apartels?
- 1 slot / 5 units
As per BP 344, how much is the parking slot width for handicapped drivers and passengers providing sufficient clear space between parked cars to allow them to transfer to wheelchair?
3.70 meters
As per PD 1096, what is the minimum front setback for a Residential R-1 lot?
4.50 meters
As per PD 1096, what is the minimum ceiling height of the first storey of a habitable room provided with artificial ventilation?
- 2.70m
What basic principle is applied in the basic planning requirements of BP 344 standards so that finding a person’s way inside and outside of a building or room space shall be made easy for everyone?
- Orientation
A bar which extends across at least ½ of each door leaf, which will open the door if subjected for pressure.
Panic Hardware
What is the minimum floor area for economic housing units as provided for in BP 220?
22m²
As per PD 1185, dwelling units in row apartments shall be separated from each other by partition walls having a fire resistance rating of how many hours?
- 4 hours
As per BP 220, what is the minimum distance between two buildings wherein the taller building has 3 or 4 storeys?
- 6 meters
Remedial work done on any damaged or deteriorated portion/s of building/ structure to restore to its original condition.
Repair
As per PD 1096, under what classification shall gasoline filling and service stations be classified?
- Business and Mercantile
As per BP 220, how many percent of the gross subdivision area shall be allocated for parks and playgrounds if the density in 250 dwelling units per hectare in socialized housing?
- 9%
As per BP 344, a level area of not less than how many meters shall be provided at the top and bottom of any ramp?
1.80 m2
For residential occupancies, how many percent of an interior lot is open space?
- 50%
As per BP 344, entrances with vestibules shall be provided with at least ____ depth to allow a disabled person to open the doors and his wheelchair to pass through easily?
3.00m
. What is the maximum floor area for open market housing units as per PD 957?
- 42 sq. meters
As per PD 957, what is the minimum lot frontage of an interior lot for single-detached units?
3.00m
As per BP 344, a lever area of not less than ____ meters shall be provided at the top and bottom of any ramp.
1.80m
An interest in real property consisting of a separate interest in a unit in a residential, industrial, or commercial buildings and an undivided interest in common directly or indirectly, in the land on which it is located and in other common areas of the building.
- Condominium
As per BP 220, what is the minimum distance between buildings with more than 4 storeys?
10.00m
As per BP 220, what is the maximum length of an alley in a residential block?
- 60 meters
As per BP 344, centerline heights of the topmost control buttons or switches shall be how much from the floor so as they are within reach of a person seated on a wheelchair?
0.90 to 1.20 meters
As per PD 1096, what is the minimum front setback for a Residential R- 1 lot?
- 4.50 meters
A change in the use or occupancy of buildings/ structures or any portions thereof, which has different requirements.
Conversion
As per PD 1096. What is referred to by the total number of persons that may occupy a building or a portion thereof at any one time?
Occupant Load
As per PD 1096, what is the minimum width of a dimension of a court?
2.00m
As per PD 1096, what is the ratio of parking slot to gross floor area of office buildings?
- 1 slot / 125 sq. meters
As per Pd 957, what is the minimum lot frontage of an interior lot for single- detached units?
- 3 meters
As per PD 957, what is the prescribed ratio for saleable and non- saleable lots?
- 70% / 30%
As per PD 1096, how many percent or parking requirements may be provided if adequate public parking lots/multi-floor parking garages are available within 200 meters of the proposed building/structures?
20% / Twenty Percent
As per BP 220, what is the maximum length for row house units?
- 100 meters
As per BP 220, maintain a ratio for house and lot where ___ % of the selling price for a house and lot package is allotted for the house and ___ % for the lot.
- 60% / 40%
A dwelling on one lot containing separate living units for 3 or more families, usually provided with commons access, services, and use of land?
Multi-family dwelling
As per PD 1096, what is the size of automobile parking slot for perpendicular diagonal parking?
2.5 x 5 meters
As per BP 344, what is the maximum length of a ramp if the ramp gradient is 1:12?
- 6 meters
. Which is not a ground for the non- issuance suspension or revocation of a Building Permit?
- Non- compliance to code
- Inaccurate application
- Non- submittal of log book
- Unauthorized change in plan
- Non- submittal of log book
As per PD 1096, what is the size of automobile parking slot for perpendicular or diagonal parking?
- 2.5 x 5 meters