Reviewer 1 Flashcards

1
Q

As per PD 1185, what is the minimum number of exits for Class A places of assembly with a capacity of more than 1,000 persons?

A
  1. 4
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is referred to in works to building/ structures involving changes in the materials used, partitioning, location/ size of openings, structural parts, existing utilities and equipment but does not increase the building height and/ or floor area?

A
  1. Alteration
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

As per PD 1096, what is the minimum clearance between the established grade of a street and/ or sidewalk and the lowest understructure of any part of a projecting balcony?

A
  1. 3.00 m
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

As per BP 344, how much is the parking slot width for handicapped drivers and passengers providing sufficient clear space between parked cars to allow them to transfer to a wheel chair?

A
  1. 3.7 meters
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the minimum lot frontage for row house units in economic housing as provided for in BP 220?

A
  1. 3.5 meters
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

As per PD 1096, what is the minimum clear ceiling height for mezzanine floors above and below it?

A

1.80m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

As per BP 344, how long is the extension of handrails which shall be provided from the start and end of ramps and stairs?

A
  1. 300 mm.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

As per PD 1096, what is the ratio of parking slot to number of units in residential hotels and apartels?

A
  1. 1 slot / 5 units
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

As per BP 344, how much is the parking slot width for handicapped drivers and passengers providing sufficient clear space between parked cars to allow them to transfer to wheelchair?

A

3.70 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

As per PD 1096, what is the minimum front setback for a Residential R-1 lot?

A

4.50 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

As per PD 1096, what is the minimum ceiling height of the first storey of a habitable room provided with artificial ventilation?

A
  1. 2.70m
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What basic principle is applied in the basic planning requirements of BP 344 standards so that finding a person’s way inside and outside of a building or room space shall be made easy for everyone?

A
  1. Orientation
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A bar which extends across at least ½ of each door leaf, which will open the door if subjected for pressure.

A

Panic Hardware

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the minimum floor area for economic housing units as provided for in BP 220?

A

22m²

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

As per PD 1185, dwelling units in row apartments shall be separated from each other by partition walls having a fire resistance rating of how many hours?

A
  1. 4 hours
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

As per BP 220, what is the minimum distance between two buildings wherein the taller building has 3 or 4 storeys?

A
  1. 6 meters
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Remedial work done on any damaged or deteriorated portion/s of building/ structure to restore to its original condition.

A

Repair

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

As per PD 1096, under what classification shall gasoline filling and service stations be classified?

A
  1. Business and Mercantile
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

As per BP 220, how many percent of the gross subdivision area shall be allocated for parks and playgrounds if the density in 250 dwelling units per hectare in socialized housing?

A
  1. 9%
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

As per BP 344, a level area of not less than how many meters shall be provided at the top and bottom of any ramp?

A

1.80 m2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

For residential occupancies, how many percent of an interior lot is open space?

A
  1. 50%
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

As per BP 344, entrances with vestibules shall be provided with at least ____ depth to allow a disabled person to open the doors and his wheelchair to pass through easily?

A

3.00m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

. What is the maximum floor area for open market housing units as per PD 957?

A
  1. 42 sq. meters
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

As per PD 957, what is the minimum lot frontage of an interior lot for single-detached units?

A

3.00m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
As per BP 344, a lever area of not less than ____ meters shall be provided at the top and bottom of any ramp.
1.80m
26
An interest in real property consisting of a separate interest in a unit in a residential, industrial, or commercial buildings and an undivided interest in common directly or indirectly, in the land on which it is located and in other common areas of the building.
1. Condominium
27
As per BP 220, what is the minimum distance between buildings with more than 4 storeys?
10.00m
28
As per BP 220, what is the maximum length of an alley in a residential block?
1. 60 meters
29
As per BP 344, centerline heights of the topmost control buttons or switches shall be how much from the floor so as they are within reach of a person seated on a wheelchair?
0.90 to 1.20 meters
30
As per PD 1096, what is the minimum front setback for a Residential R- 1 lot?
1. 4.50 meters
31
A change in the use or occupancy of buildings/ structures or any portions thereof, which has different requirements.
Conversion
32
As per PD 1096. What is referred to by the total number of persons that may occupy a building or a portion thereof at any one time?
Occupant Load
33
As per PD 1096, what is the minimum width of a dimension of a court?
2.00m
34
As per PD 1096, what is the ratio of parking slot to gross floor area of office buildings?
1. 1 slot / 125 sq. meters
35
As per Pd 957, what is the minimum lot frontage of an interior lot for single- detached units?
1. 3 meters
36
As per PD 957, what is the prescribed ratio for saleable and non- saleable lots?
1. 70% / 30%
37
As per PD 1096, how many percent or parking requirements may be provided if adequate public parking lots/multi-floor parking garages are available within 200 meters of the proposed building/structures?
20% / Twenty Percent
38
As per BP 220, what is the maximum length for row house units?
1. 100 meters
39
As per BP 220, maintain a ratio for house and lot where ___ % of the selling price for a house and lot package is allotted for the house and ___ % for the lot.
1. 60% / 40%
40
A dwelling on one lot containing separate living units for 3 or more families, usually provided with commons access, services, and use of land?
Multi-family dwelling
41
As per PD 1096, what is the size of automobile parking slot for perpendicular diagonal parking?
2.5 x 5 meters
42
As per BP 344, what is the maximum length of a ramp if the ramp gradient is 1:12?
1. 6 meters
43
. Which is not a ground for the non- issuance suspension or revocation of a Building Permit? 1. Non- compliance to code 2. Inaccurate application 3. Non- submittal of log book 4. Unauthorized change in plan
1. Non- submittal of log book
44
As per PD 1096, what is the size of automobile parking slot for perpendicular or diagonal parking?
1. 2.5 x 5 meters
45
As per BP 220, which is not a site criteria for determining whether an economic and socialized housing shall be allowed?
1. Climate condition
46
As per PD 957, parks/ playground or other recreational facilities may not be required if the condominium is located not more than or ___ meters from a publicly accessible park/ playground or other recreational facilities.
1. 600
47
As per PD 1096, what is the minimum clear width for Group A dwelling?
0.75 m
48
As per PD 1096, what is the minimum width for access road to interior lots?
3m
49
As per BP 344, what is the required minimum walkway width to permit a person in wheelchair to traverse it safely?
1.20 meters
50
What is referred to in works to building/ structures involving changes in the materials used, partitioning, location/size of the openings, structural parts, existing utilities and equipment but does not increase the buildings height and/or floor area?
Alteration
51
As per BP 220, maintain a ratio for house and lot where \_\_% of the selling priced for a house and lot package is allotted for the house and \_\_% for the lot.
60%/40%
52
As per PD 1185, what is the minimum width of run exclusive of nosing or projection for class B stairs?
0.23m
53
As per BP 220, what is the minimum clear width of stairways?
1. 0.60 meters
54
Which is not a requirement in applying for Building Permit?
1. Latest Income Tax
55
As per BP 220, how many percent of the gross subdivision area shall be allocated for community facilities if the density isn’t more than 150 dwelling units / hec. in socialized housing?
1. 1%
56
As per PD 957, what is the minimum floor area of family condominium units for open market?
36
57
An extremely hot luminous bidge formed by passage of an electric current across a space between two conductors or terminals due to the incandescence of the conducting vapor.
1. Electric Arc
58
Descriptive of any material which by its nature or as a result of its reaction with other elements produces a rapid drop in temperature of the immediate surroundings
1. Cryogenic
59
What is the minimum lot area for open market rowhouse units as prescribed in PD 957?
60m²
60
As per PD 1096, what is the minimum width for access road to interior lots?
1. 3m
61
As per PD 1185, what is the minimum aisle width for less than 60 seats in places of assembly?
1. 0.76 meters
62
As per BP 344, accessible public washrooms and toilets shall permit easy passage of a wheelchair and must show how much turning space for wheelchairs?
1. 2.25 sq. m
63
For residential occupancies, how many percent of an interior lot is open space?
50%
64
Which is not considered a basis of assessment for building permit fees?
1. Lot Area
65
As per BP 220, what is the minimum dimension for stairway tread and riser respectively?
200/250mm
66
As per PD 1185, what is the minimum width for any single door in a doorway?
710mm
67
As per PD 1185, what is the minimum headroom clearance for class B stairs?
2.00m
68
What is the minimum lot area for single-detached socialized housing units as provided in BP 220?
64m²
69
As per BP 220, what is the minimum dimension for stairway tread and riser respectively?
0.20m
70
As per PD 1096. What is the minimum ceiling height of the first storey of a habitable room provide with artificial ventilation?
2.70m
71
As per PD 1096, how many percent or parking requirements may be provided if adequate public parking lots/ multi- floor parking garages are available within 200 meters of the proposed buildings/ structures?
1. 20%
72
As per BP 344, how many seats shall be designated for disabled persons in passenger trains?
1. 6
73
As per BP 344m how long is the extension of handrails which shall be provided from the start and end of ramps and stairs?
300mm
74
As per PD 1185, under what classification does fire in flammable liquids and gasses belong to?
1. Class B
75
As per PD 1096, what is the minimum distance of accessible parking area for the physically handicapped from facility being served?
1. 60 meters
76
As per PD 1096, a wheelchair transfer area is required for every how many parking spaces in buildings/ structures intended for the use or occupancy of the handicapped?
1. 2 spaces
77
As per BP 344, what is the maximum distance between rest steps of spaces in walkways?
1. 11 meters
78
As per PD 957, what is the minimum width for roads or right- of- way for residential condominium projects?
1. 8 meters
79
A bar which extends across at least one- half of each door leaf, which will open the door if subjected to pressure.
**PANIC HARDWARE**
80
As per PD 1096, what is the classification of buildings of masonry and wood construction with a one- hour fire resistivity throughout and exterior walls of incombustible fire- resistive construction?
1. Type 3
81
As per PD 1185, what is the minimum headroom clearance for Class B stairs?
1. 1.95 m
82
As per BP 344 entrances with vestibules shall be provided with at least how much depth to allow a disabled person to open the door and allow his wheelchair to pass through easily?
1. 3.0 meters
83
As per PD 1185, what is the minimum width of run exclusive of nosing or projection for Class B stairs?
1. 0.23 m
84
Which of the following is not covered in the framework of minimum standards and requirements for buildings under PD 1096?
1. Aesthetic value
85
86
Any physical change made on buildings/ structures to increase the value, quality, and/ or to improve the aesthetic.
Renovation
87
What is the minimum floor area for economic housing units as provided for in BP 220?
1. 22 sq. meters
88
As per PD 1096. Under what classification shall gasoline filling and service stations be classified?
Business and Mercantile
89
As per PD 1185, buildings over the height shall be required throughout with automatic fire sprinkler system.
1. 15m
90
As per PD 1096, what is the minimum clear width for Group A dwelling stairs?
1. 0.75 m
91
As per PD 957, what is the minimum area for a single park/playground in a residential condominium project?
50m²
92
As per PD 1096, what is the minimum clear ceiling height for mezzanine floors above and below it?
1. 1.80 m
93
As per PD 1185,what is the unit of exit width used to measure means of egress?
1. 55 cm
94
What is the minimum lot frontage for now house units economic housing as provided for in BP 220?
3.5 meters
95
As per PD 1096, what is the minimum air space per person for a habitable room with natural ventilation?
1. 14 cu m
96
As per PD 1096, under what classification shall factories and workshops using less flammable or non- combustible materials be classified?
1. Business and Mercantile
97
As per BP 344, what is the required minimum walkway width to permit a person in wheelchair to traverse it with safety?
1. 1.20 meters
98
Failure to commence the work within a period of ______ months from the date of issuance of permit is a basis for non-issuance, suspension or revocation of building permit.
Twelve (12)
99
As per PD 1185, what is the minimum width for any single doors in a doorway?
0.60m
100
What is the minimum lot frontage of a regular lot for single- detached units as provided for in BP 220?
8m
101
As per PD 1096, what is the minimum clearance between the established grade of a street and/or sidewalk and the lowest undersurface of any part of a projecting balcony?
3.00m
102
As per PD 1096, a wheelchair transfer area is required for every how many parking spaces in buildings/structures intended for the use or occupancy of the handicapped?
two spaces (2)
103
As per BP 220, what is the minimum area for parks and playgrounds?
1. 100 sq. meters
104
As per PD 1185, what is the maximum travel distance for places of assembly if not protected by automatic fire suppression system?
46 meters
105
As per PD 1185, dwelling units in row apartments shall be separated from each other by partition walls having a fire resistance rating of how many hours?
4 Hours
106
As per BP 220, how many percent of the gross subdivision area shall be allocated for community facilities if the density is not more than 150 dwelling units per hectare in socialized housing?
One Percent (1%)
107
As per PD 1096, what is the minimum width dimension of a court?
1. 2.00 m
108
Failure to commence the work within a period of ____ months from the date of issuance of permit is a basis for non- issuance, suspension or revocation of a building permit.
1. 12
109
As per PD 1185, what is the maximum travel distance for places of assembly if not protected by automatic fire suppression system?
1. 46 meters
110
As per PD 1096, what is referred to by the total number of persons that may occupy a building or a portion thereof at any one time?
1. occupant load
111
As per PD 1185, every room or space in educational occupancies with a capacity of over 50 persons shall have at least how many doorways?