Prac x yesa Flashcards

1
Q

As per PD 1096, what is the minimum clear width for Group A dwelling?

A

0.75m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

As per PD 1096, what is the minimum width for access road to interior lots?

A

3m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

For residential occupancies, how many percent of an interior lot is open space?

A

50%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

As per PD 1096, how many percent or parking requirements may be provided if adequate public parking lots/multi-floor parking garages are available within 200 meters of the proposed building/structures?

A

20% / Twenty Percent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

As per PD 1096. What is referred to by the total number of persons that may occupy a building or a portion thereof at any one time?

A

Occupant Load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is referred to in works to building/ structures involving changes in the materials used, partitioning, location/size of the openings, structural parts, existing utilities and equipment but does not increase the buildings height and/or floor area?

A

Alteration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

As per PD 1096. What is the minimum ceiling height of the first storey of a habitable room provide with artificial ventilation?

A

2.70m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

As per PD 1096, a wheelchair transfer area is required for every how many parking spaces in buildings/structures intended for the use or occupancy of the handicapped?

A

two spaces (2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

As per PD 1096, what is the minimum clear ceiling height for mezzanine floors above and below it?

A

1.80m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Failure to commence the work within a period of ______ months from the date of issuance of permit is a basis for non-issuance, suspension or revocation of building permit.

A

12 months

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

As per PD 1096, what is the minimum width of a dimension of a court?

A

2.00m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

As per PD 1096, what is the minimum clearance between the established grade of a street and/or sidewalk and the lowest undersurface of any part of a projecting balcony?

A

3.00m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

As per PD 1096. Under what classification shall gasoline filling and service stations be classified?

A

Business and Mercantile

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

As per PD 1096, what is the size of automobile parking slot for perpendicular diagonal parking?

A

2.5 x 5 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

As per PD 1096, what is the minimum front setback for a Residential R-1 lot?

A

4.50 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

As per BP 344, how much is the parking slot width for handicapped drivers and passengers providing sufficient clear space between parked cars to allow them to transfer to wheelchair?

A

3.70 meters

17
Q

As per BP 344, what is the required minimum walkway width to permit a person in wheelchair to traverse it safely?

A

1.20 meters

18
Q

As per BP 344, a lever area of not less than ____ meters shall be provided at the top and bottom of any ramp.

A

1.80m

19
Q

What is the minimum floor area for economic housing units as provided for in BP 220?

A

22m²

20
Q

As per PD 957, what is the minimum lot frontage of an interior lot for single-detached units?

A

3.00m

21
Q

As per BP 220, what is the minimum dimension for stairway tread and riser respectively?

A

0.20m

22
Q

What is the minimum lot frontage for now house units economic housing as provided for in BP 220?

A

3.5 meters

23
Q

As per BP 344m how long is the extension of handrails which shall be provided from the start and end of ramps and stairs?

A

300mm

24
Q

As per BP 220, maintain a ratio for house and lot where __% of the selling priced for a house and lot package is allotted for the house and __% for the lot.

A

60%/40%

25
Q

As per BP 344, entrances with vestibules shall be provided with at least ____ depth to allow a disabled person to open the doors and his wheelchair to pass through easily?

A

3.00m

26
Q

As per BP 220, how many percent of the gross subdivision area shall be allocated for community facilities if the density is not more than 150 dwelling units per hectare in socialized housing?

A

One Percent (1%)

27
Q

As per PD 957, what is the minimum area for a single park/playground in a residential condominium project?

A

50m²

28
Q

As per BP 220, what is the minimum distance between buildings with more than 4 storeys?

A

10.00m

29
Q

As per BP 344, centerline heights of the topmost control buttons or switches shall be how much from the floor so as they are within reach of a person seated on a wheelchair?

A

0.90 to 1.20 meters

30
Q

As per PD 957, what is the minimum floor area of family condominium units for open market?

A

36

31
Q

A dwelling on one lot containing separate living units for 3 or more families, usually provided with commons access, services, and use of land?

A

Multi-family dwelling

32
Q

What is the minimum lot area for single-detached socialized housing units as provided in BP 220?

A

64m²

33
Q

What is the minimum lot area for open market rowhouse units as prescribed in PD 957?

A

60m²

34
Q

As per PD 1185, dwelling units in row apartments shall be separated from each other by partition walls having a fire resistance rating of how many hours?

A

4 Hours

35
Q

As per PD 1185, what is the maximum travel distance for places of assembly if not protected by automatic fire suppression system?

A

46 meters

36
Q

As per PD 1185, what is the minimum width for any single doors in a doorway?

A

0.60m

37
Q

As per PD 1185, what is the minimum width of run exclusive of nosing or projection for class B stairs?

A

0.23m

38
Q

As per PD 1185, what is the minimum headroom clearance for class B stairs?

A

2.00m?

39
Q

A bar which extends across at least ½ of each door leaf, which will open the door if subjected for pressure.

A