Reed Monitor Flashcards
1
Q
What is the Reed Monitor and where is it located?
A
- The Reed Monitor protects the traction and auxiliary systems from potentially harmful irregularities from the OLE or disturbances from the system itself
- Located in the PTOSLW
2
Q
What are a drivers actions if the Reed Monitor is activated?
A
[When the Reed Monitor is activated, the VCB will open and TMS will display a RED fault]
- If possible stop at the next station and inform the signaller of Reed Monitor activation
- the signaller will confirm with the ECO if there is an issue with the OLE, if so the driver may be instructed to do a ‘Pan Reset’ and continue as normal or drop the pan immediately
3
Q
What are a drivers actions if the Reed Monitor fails?
A
[RED fault will display on TMS- ‘Device Failure: Reed Monitor”]
- If possible stop at the next station
- Immediately inform signaller of defective Reed Monitor
- Inform MTRC control and Siemens Depot
- A clear route must be arranged to a location where the train can be taken out of service (Ideally depot or terminus station)
- If in service, detrain passengers
[Once clear route has been confirmed]:
- Operate ‘Isolation Reed Monitor’ button- located in the MCB cupboard of PTOSLW (opposite the toilet)
[VCB will close for 30minutes in order to clear the line before it will reopen permanently]