Reactor Flashcards
What does double reduction do?
Reduces speed of turbines
What is the purpose of the Deaerating feed pumps?
- Removes oxygen to minimize corrosion
- Pressurizes water to prevent the formation of vapor air bubbles
What is in MMR1?
- 1&2 Distilling Units
- 1&2 SSTG’s
- 1&4 Main Engines
Where are CTG’s 1&2 located?
RAR1
Describe our Main Engine
- Double Reduction
- Double Helical
- Articulated
- Locked Train
- Folded
What is the purpose of the reboiler?
- To prevent contamination of the propulsion plant
- Prevents potentially contaminated radioactive steam from spreading
Describe the CTG
- Coolant Turbine Generator
- Variable Frequency
- 8MW
- 1388 AMPS
- 3 Phase
Why is the CTG variable frequency?
So that the output can raise or lower depending on how hard the reactor is working
What is significant about the SSTG’s being 60 hertz?
North American Standard
Describe our SSTG’s
- Ship’s Service Turbine Generator
- 4160V
- 60 Hz
- 8MW
- 3 Phase
What is the primary and secondary purpose of the EDG’s?
Primary- Provide power to the reactor fill pump in case of CTG failure
Secondary- Provide back up power in case of SSTG failure
Where are our reboilers located?
1- 1A Shaft Alley
2- 4B Shaft Alley
What are some services off the reboilers?
- Laundry Steam
- Galley Steam
- Hotel Services
Where are 1&2 EDG located?
-Fwd Emergency, under repair 2
Where are 3&4 EDG located?
-Aft Emergency, under repair 3