Damage Control Flashcards
What are two types of portable eductors?
S-type and Peri Jet
What is the P-100 used for?
Primary: Firefighting
Secondary: Dewatering
What is the primary purpose of eductors?
To remove water
What cools the P-100 pump while it is being used?
Air
What is the maximum lift that a P-100 can take suction?
20ft
What type of fuel does the P-100 pump utilize?
JP5
ESP
Electrical Submersible Pump
Submersible pumps are not designed for pumping what types of liquids?
Gasoline, heavy oils, and hot water
What is the maximum static head for the ESP
70ft
When using ESP’s in tandem, which pump do you start first?
The bottom one
MPE
Maximum Permissible Exposure
Who sets MPE and what is it set for default?
The CO. 150 RADS
MOPP
Mission Oriented Protective Posture
What are the 5 MOPP levels?
Levels 0-4
What type of threads are on a C-2 canister?
NATO
What is the purpose of the M-256 A1 kit?
Used to detect Nerve, Blood, and Blister agents in vapor form
What is the M-291 kit used for?
Skin decontamination. Dab onto skin, don’t rub
What color does M-9 paper turn when an agent is present?
Red
At what MOPP level is M-9 paper posted?
MOPP Level 2
What is CDU and where is it located?
Control Display Unit, located in DC Central
What is RDU and where is it located?
Remote Display Unit, located on the Bridge
What is the difference between the CDU and RDU?
Bridge doesn’t have controls. Only DC Central has control
What type of system is the IPDS?
Fixed(Stationary)
What does IPDS detect?
Chemicals; filters the air
CCA
Contamination Control Area
DS
Decontamination Station
Where do you take off your ACPG suit?
Contamination Control Area
Where do you take of your coveralls and shower?
Decontamination Station
ACPG
Advanced Chemical Protective Garment
How long is and ACPG suit good for after it has been taken out of its’ original package?
120 days
Where are our CCAs?
- Hanger Bay 1
- Hangar Bay 3
Where are our DS?
- 1 FWD by Repair 2
- 2 Mid-ship by Female Chief’s head and WEPS male berthing
- 1 AFT by RX male berthing
HTH
High Test Hypochlorite (Calcium Hypochlorite)
What is the purpose of list control?
To keep flight deck level so planes can land
How many List Control tanks do we have?
10
How many pumps run List Control?
2
What type of water is in the List Control tanks?
Potable water
Where are the List Control pumps located?
4A Shaft Alley
What is the GPM for the List Control pumps?
1800 GPM
Who operates the List Control?
DCWS
What 2 List Control tanks can hold the most water and why?
113 and 165 because they are on opposite sides of the Island
What do we use to determine list?
Clinometer
What is the RAM fan used for?
Desmoking
What powers the Ram fan?
Firemain
What safety precautions must be followed prior to energizing the RAM fan?
Ground it to prevent shock from electro-static build up
How many CFM does the RAM fan move?
2000CFM
What type of Firemain do we have?
Composite Loop
How many fire pumps do we have? How many are electrically driven? How many are steam driven?
- 19 Electric/ 4 Steam
How many Main Drainage Eductors do we have?
13
What is the purpose of Main Drainage?
Pump oil waste or water out of the bilges
Where is the FWD CHT tank located?
Pump Room 1
What type of pump is used for CHT?
Eddie Pump
What is H2S and what does it smell like?
Hydrogen Sulfide; smells like rotten eggs
How many HICAP AFFF stations do we have?
20
How many AFFF mixing stations do we have?
21
What is special about AFFF mixing stations 21?
The Bomb Farm
What stations are injection pump only?
1,2,11, & 12
What is the mixing ration for Firemain and AFFF?
94% Firemain : 6% AFFF
What is the GPM for the injection pump?
60GPM
What is the GPM for the BPP?
65GPM
What does the Pancake Valve do?
Regulates AFFF and Firemain
What does SOPV stand for?
Solenoid Operated Pilot Valve
What does SOPV do?
Energized the AFFF station
How many volts is the SOPV?
440V
Where are our reserve tanks located?
HB1- PortsideHB3- Stbdside
Where are the reserve pumps located?
AFFF Stations 6 and 13
What is the GPM for the reserve pumps?
360 GPM
How many Halon Boards do we have?
9
What activates the Halon Boad?
5lb CO2 bottle
Where are the Halon boards located?
- FWD/AFT EDG
- Pump Room 2
- Pump Room 3
- Shaft Alleys
What do the lights mean on the Halon Board?
White- Power Available
Amber- Halon Activated
Red- Halon Discharge
Green- Vent Damper
What does the 30 sec time delay mean?
Time to evacuate space
How many CO2 Fixed Flooding Systems o we have? Where are they located?
4; in the HAZMAT store rooms (3 FWD, 1 AFT)
How many SCBA recharge stations do we have? Where are they located?
8:
- 1F
- 1B
- 1A
- 2
- 3
- 7F
- 7B
How do you activate the CO2 Fix Flooding system?
Pull the T-shaped handle until you see red on the cable
How many EBACS do we have? Where are they located?
2:
1 Fwd STBD Side
1 Aft next to the Jet Shop
If we lose HP air, what do we use to fill the SCBA bottles?
EBACs (Emergency Breathing Air Compressors)
Who is the DCA assistant to?
CHENG
What is the R&A team?
Rescue and Assistance team; back up to the flying squad
What NSTM can you find information about surface ship fire fighting?
NSTM 555
Describe the 4 classes of fires
Alpha- Leaves ashes
Bravo- HAZMAT, Fuel, Oil
Charlie- Electrical
Delta- Combustible Metal
Name the sides of the fire triangle
Oxygen, Fuel, Heat
List the 10 repair lockers
- 1A, 1B, 1F
- 2,3,4,5
- 7A, 7B, 7F
If DC Central goes down, where is Secondary Central located?
Repair 3
What does PKP stand for?
Potassium Bicarbonate
What is the effective range of the 18lb PKP bottle?
19ft
What is the effective range of the 27lb PKP bottle?
21ft
How does PKP extinguish a fire?
Interrupts the chemical reaction
What type of fire does PKP primarily put out?
Class Bravo
What is the effective range of the CO2 extinguisher?
4-6ft
In continuous operation, how long does the 15lb CO2 extinguisher last?
40 Seconds
Before you squeeze the lever to release the C02, what must you do?
Ground the cylinder to the deck when discharging to avoid shock from static electricity
How does C02 extinguish a fire?
Displaces oxygen
What are the best woods for shoring and why?
Douglas Fur and Yellow Pine because they expands when absorbing water
What are he 2 size of metal shores?
3-5 FT and 6-11 FT
What is the vertical load strength of a 3-5ft metal shore?
3ft- 20,000 lbs5ft- 12,000 lbs
What is the vertical load strength of a 6-11ft metal shore?
6ft- 20,000 lbs11ft- 6,000 lbs
List the different types of shoring
I- Direct PressureH- No deck anchorageK- Triangular perpendicular
What is the strongest type of shoring?
I
What is the weakest type of shoring?
H
APC
Aqueous Potassium Carbonate
What is the APC system used for?
Protection from galley deep-fat and doughnut fryers and their exhaust system
How does APC extinguish a fire?
Combines with the hot cooking oil to cut oxygen out
Where can you find APC
Galley
Who carries the NFTI?
Team Leader
NFTI
Naval Firefighting Thermal Imager
How many non-rechargeable batteries does the NFTI require and how long do they last?
10 AA alkaline; 3.05 hours
What type of rechargeable batteries does the NFTI require and how long do they last?
Lithium Ion; 4.85 hours
Who wears a 30 min SCBA bottle?
Investigators, Boundary Men, and Access Men
Who wears a 45 min SCBA Bottle?
The Hose Team
Who is overall in charge of the hose team?
Team Leader
What persent of air do you have left in your SCBA when the Vibra-Alert goes off?
20%-25%
Who is the DCO/CHENG?
Captain Select Latterman
Who is the DCA?
Lt Cdr Payne
Who is the ADCA?
CWO2 Franklin
Who is the Firemarshall?
Lt Sales
Where is 7F located?
03, near frame 17
Where is 7B located?
03, beneath the island
Where is 7A located?
03, near 255 frame
Where is 2 located?
Near battlemart
Where is 4 located?
Near Security
Where is 5 located?
Aft Mess Decks
Where is 3 located?
XO’s Pway
Name the kits in the repair locker
Shoring Kit Banding Kit Gas Free Kit Banding Kit Pipe Patching Kit
What else can you find in the repair locker?
NFTI,Stretcher, PECU
What are the 3 stages of a fire?
Growth, Flashover, Fully Developed, Decay
What manual has procedures for handling casualties?
RPM(Repair Party Manual)
Describe the AFFF stations
- 600 gallons each
- tanks are 90/10 copper nickel
- activated with SOPV (440V)
- 4 are injection only