Procedures and Flows Flashcards
1
Q
Determine Aircraft NOT POWERED
A
Lights - Off
DUs - Off
2
Q
Determine aircraft partially powered
A
(LIDs ON, Batts - OFF)
Lights - on
“IN USE”
DUs - on
Batts - off
3
Q
Determine aircraft fully powered
A
Lights on
DUs on
Batts On
APU or GPU power
4
Q
Power assessment and establishment
A
- Disconnect from ground service bus
- First 4 common items - ALWAYS wait for EICAS to stop scrolling
- If fully powered (DUs-on,“IN USE”, BATTs-ON) - move on to interior inspection
- do not accomplish Elec Pwr On ✔️
- If partially powered (DUs-on, Ext pwr-”IN USE”, BATTs 1+2-OFF) - move on to interior inspection
- do not accomplish Elec Pwr On ✔️
- If aircraft not powered, accomplish accomplish Elec Pwr On ✔️
- accomplish interior inspection items during EICAS scrolling
Electrical Power On ✔️
- L CTP →CHKL; PROC >SUPP PROC >Elect pwr on ✔️
- If ext pwr “AVAIL”, “IN USE” / if not avail, start APU
- Accomplish exterior inspection while IRS system aligns
- check CMS water and waste
- complete Elect pwr on ✔️
- If ext pwr “AVAIL”, “IN USE” / if not avail, start APU
5
Q
***Interior Inspection
A
Begin by opening the ECL - DON’T JUMP AHEAD!
- R CTP → CHKL >PROC >SUPP PROC> Interior Inspection
- Flight deck security search
- Emergency equipment
- Req’d docs, jump seat, pins, EFB mount, vests, screens, hatch, rope, luggage, paper
- EICAS and info (including Synoptic pages)
- EICAS: check msgs, quantities (oil, hydraulic, fuel, oxygen), green rudder trim
- Status pg: oil, tire px - green, brake temp - green, no amber wear indicators
- Cycle through SYN pgs, check for abnormals
- this is NOT time to perform ICE DETECT test on AVIONICS tile
- INFO msgs - acknowledge, CBs (notify Mx of any irregularities)