Pressure relief system works by limiting the maximum discharge pressure by ____ and ____ side of pump.
opening a gate / bypassing water back to inlet
The operating range of the pressure relief valve is between ____.
70 and 300 psi.
If pressures greater than ___ are required, the relief valve must be OFF
300 psi
Always reduce pump pressure using engine throttle ___ turning the relief valve off.
BEFORE
When the relief valve is OFF, or out of operation, the relief valve is held closed by ___.
hydraulic force
Maintain intake pressure at or above ___ when operating from a pressurized external supply.
20 PSI
When operating from draft, always maintain ____ or less. Intake vacuum of more than ___. can cause pump to cavitate.
20 in. Hg. of vacuum
Pump cavitation is happening when: Discharge pressure changes ____.
up and down
Pump cavitation is happening when: You hear a sound like _____ in the pump.
gravel churning
Pump cavitation is happening when: Discharge pressure remains the same when you change____.
engine speed
The FoamPro 2001 will power when the pump shift lever is placed in to ____.
Pump mode
The foam system is rated at ___ at 3.0% and ___ at 0.5%
85 gpm / 500 gpm
Turn Foam Controller ON. The LED lamps below ____ will illuminate. The ____ LED will flash. The current rate of water flow will display in gallons per minute.
ON and FLOW / ON
To Stop Pumping Foam and Flush System: Press the ___ button to set the system in standby mode. The foam pump will stop.
red FOAM
Priming the Foam System: Turn the CAL/INJECT valve to the ___ position.
CALIBRATE