Pressure Relief Valve/ Foam Pro Flashcards

1
Q

Pressure relief system works by limiting the maximum discharge pressure by ____ and ____ side of pump.

A

opening a gate / bypassing water back to inlet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The operating range of the pressure relief valve is between ____.

A

70 and 300 psi.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If pressures greater than ___ are required, the relief valve must be OFF

A

300 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Always reduce pump pressure using engine throttle ___ turning the relief valve off.

A

BEFORE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When the relief valve is OFF, or out of operation, the relief valve is held closed by ___.

A

hydraulic force

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Maintain intake pressure at or above ___ when operating from a pressurized external supply.

A

20 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When operating from draft, always maintain ____ or less. Intake vacuum of more than ___. can cause pump to cavitate.

A

20 in. Hg. of vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Pump cavitation is happening when: Discharge pressure changes ____.

A

up and down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Pump cavitation is happening when: You hear a sound like _____ in the pump.

A

gravel churning

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Pump cavitation is happening when: Discharge pressure remains the same when you change____.

A

engine speed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The FoamPro 2001 will power when the pump shift lever is placed in to ____.

A

Pump mode

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The foam system is rated at ___ at 3.0% and ___ at 0.5%

A

85 gpm / 500 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Turn Foam Controller ON. The LED lamps below ____ will illuminate. The ____ LED will flash. The current rate of water flow will display in gallons per minute.

A

ON and FLOW / ON

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

To Stop Pumping Foam and Flush System: Press the ___ button to set the system in standby mode. The foam pump will stop.

A

red FOAM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Priming the Foam System: Turn the CAL/INJECT valve to the ___ position.

A

CALIBRATE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Priming the Foam System: With the pump running, observe ____ from the CAL/INJECT valve to see ____.

A

the hose / foam flowing from the foam unit.

17
Q

Priming the Foam System:
When foam flows from the unit and can be seen in the hose, the pump is primed. Turn the valve to ____ and you may resume foam operations.

A

INJECT

18
Q

Mixing of different foam concentrates (either type or manufacturer) may cause _____.

A

deterioration of the foam concentrate, improper proportioning, and poor performance in a fire situation.

19
Q

Mixing of Class A and Class B foam concentrates may result in a chemical reaction that can create ____, which can clog orifices and cause system failure.

A

globules