PR S 400027 Flashcards
Traction return
what type of works can impact traction return
re railing
disconnection of impedance bonds
disconnection of negative return cables
what must be ensured when breaking traction return
adequate alternative traction return paths are available.
what are the three methods for ensuring traction return is continuous
temporary bonding to provide an alternative traction path,
bonding to a piece of rail adjacent to the worksite and bonding that to rails either side of the cut.
connection to the overheads. requires signing onto electrical permit, OHW to remain continuous, traction rails are bonded at the break, no breaks allowed up OHW connection is in place.
what permit is required for disconnection of all substation or section hunt connections
a substation access permit
how do you protect track circuits from stray traction currents
disconnection of incoming or outgoing track leads
Minimum traction rail exemptions
1 in 3 rails can be cut, 2 in 6 rails can be cut without providing alternative traction return.