PowerMax and VMAX Family Solutions Design (PowerMax and VMAX All Flash Design Options) Flashcards
What PowerMax components must be balanced across engines?
RAID Groups
IO Modules
Emulations
Cache
DAEs
What are the max IOPS on PowerMax 2000?
2.7M
What are the max IOPS on PowerMax 8000?
15M
What are the max IOPS on VMAX 250F?
1M
What are the max IOPS on VMAX 950F?
6.7M
What is the usable capacity on PowerMax/VMAX?
physical capacity that is stored within Storage Resource Pools
How is usable capacity accessed on PowerMax/VMAX?
accessed by hosts using thin provisioned devices called TDEVs
What is the TDEV capacity on PowerMax/VMAX?
effective capacity
What is true about adding drives on PowerMax/VMAX?
can intermix drive sizes in the same system
What is Automated Data Placement on PowerMax/VMAX?
ability of system to intelligently manage data placement between two different drive technologies in the same system
What are Advanced Wear Analytics on PowerMax/VMAX?
help to manage drives in storage tier and make it easy to add and rebalance
ensure write distribution
What PowerMax/VMAX system doesn’t support different cache sizes between engines?
VMAX 950F
When does PowerMax 2000 support engines w/ different cache sizes?
in dual Brick systems only
When does PowerMax 8000 support engines w/ different cache sizes?
requires minimum of 4 bricks
When does VMAX 950F support engines w/ different cache sizes?
in dual Brick systems only
What is the Optimized service level?
designed to use all allowable resources and it not managed to assist any other SLs
no target, upper or lower response time
What attributes do Bronze and Silver SLs have?
have target, upper, and lower response time designed to allow higher priority SLs to be unaffected
How are Bronze and Silver SLs designed?
such that their average response time will be greater than or equal to the lower response limit
What attributes do Gold, Platinum and Diamond SLs have?
have target and upper response time limit
have highest priority for performance
How is RAID setup in PowerMax/VMAX?
use a single RAID scheme for the entire system
all additional bricks and devices use same RAID scheme as initial usable capacity regardless of drive size by new drive pack
How is the RAID determined on PowerMax/VMAX?
determined by initial usable capacity
What RAID schemes are supported on PowerMax 2000?
RAID 5 (7+1) default
RAID 5 (3+1)
RAID 6 (6+2)
What RAID schemes are supported on PowerMax 8000?
RAID 5 (7+1) default
RAID 6 (6+2)
What RAID schemes are supported on VMAX 250F?
RAID 5 (7+1) default
RAID 5 (3+1)
RAID 6 (6+2)
What RAID schemes are supported on VMAX 950F?
RAID 5 (7+1) default
RAID 6 (14+2)
How does RAID 5 work?
uses rotating parity across all drives in the group
How does RAID 6 work?
uses both horizontal and diagonal parity distributed across all drives in group
What are the performance characteristics of RAID 5?
Fast Read
Good Write
What are the performance characteristics of RAID 6?
Fast Read
Fair Write
What is the typical workload skew for storage systems?
85/15
What are the available IO Modules on PowerMax?
iSCSI (10G)
Fibre Channel (16G, 32G)
eNAS (10G SFP or Ethernet)
eNAS Tape Backup (8G FC)
FICON (16G)
What IO Module is only available on PowerMax 8000 and VMAX 950F?
FICON
can be single or multimode
What IO Modules only come w/ 2 ports on PowerMax?
eNAS
eNAS Tape Backup
What are the IO Modules available on VMAX?
Fibre Channel (8G, 16G)
iSCSI (10G)
eNAS (10G SFP/Ethernet)
eNAS Tape Backup (8G FC)
FICON (16G)
SRDF (Ethernet)
What protocol is available on PowerMax but not VMAX?
NVMe/FC
must have 32G FC IO Module
How does PowerMax/VMAX scale up?
adding capacity packs
each pack has multiples of 13TBu (11 or 13TBu if it’s a VMAX 250F)
How does PowerMax/VMAX scale out?
adding more bricks w/ included capacity in the system
How must PowerMax engines be configured?
all engines must be configured identically w/ respect to SCM for IO balance
same RAID scheme