PowerMax and VMAX All Flash Solutions Design (VMAX All Flash Models) Flashcards
What are the racking options for VMAX 950F?
support for single V-Brick in bay
bay dispersion
systems bay 2 through 4 up to 25 meters from system bay 1
What is the service access available on VMAX 250F?
onsite connectivity with service laptop
What is the service access available on VMAX 950F?
Keyboard, Video, Mouse (KVM) component in System Bay 1
service tray on additional system bays
What is the host connectivity available on VMAX 250F?
Open Systems (OS)
What is the host connectivity available on VMAX 950F?
Open Systems (OS)
Mainframe (MF)
Mixed (OS and MF)
What are the maximum drives in a V-Brick on VMAX 250F?
50
What are the maximum drives in a V-Brick on VMAX 950F?
240
What are the power options on VMAX?
three phase delta (50 amp), WYE (32 amp), single phase (32 amp)
What is the vaulting process on VMAX?
vault to flash in engine
What are the vBrick scalability of VMAX 250F?
1-2
What are the vBrick scalability of VMAX 950F?
1-8
What is the range of cores available on a vBrick on VMAX 250F?
48-96
What is the range of cores available on a vBrick on VMAX 950F?
72-576
What are the cache options on a vBrick on VMAX 250F?
512GB, 1TB, 2TB
What are the cache options on a vBrick on VMAX 950F?
1TB, 2TB
What is the max cache per array on VMAX 250F?
4TB
What is the max cache per array on VMAX 950F?
16TB
What are the maximum drives per array on VMAX 250F?
100
What are the maximum drives per array on VMAX 950F?
1920
What type of DAEs are available on VMAX 250F?
25 drive
What type of DAEs are available on VMAX 950F?
120 drive
What is the minimum capacity on VMAX 250F?
11TBu
What is the minimum capacity on VMAX 950F?
53TBu (OS)
13TBu (MF)
What are the capacity increments you need to scale VMAX in?
13TBs
What is the maximum usable capacity on VMAX 250F?
1PBe
What is the maximum usable capacity on VMAX 950F?
4PBe
What are the max FE ports for VMAX 250F?
64
What are the max FE ports for VMAX 950F?
192 (OS)
256 (MF)
What are the Infiniband connectivity options on VMAX?
none on 250F (direct IB connections)
dual 18 port switches on 950F
What are the software package options on PowerMax?
F
FX
zF
zFX
What is included in the F Software package?
HYPERMAX OS
thin provisioning
inline compression
non-disruptive migration
virtual volumes (vVols)
QoS
Host IO Limits
eManagement
TimeFinder SnapVX
AppSync Starter Bundle
What is HYPERMAX OS?
provides emulations that performs specific data service and control functions
What is thin provisioning?
storage is created and allocated from a common pool on an as-needed basis
remainder of physical storage is available for use when asked
What is non-disruptive migration on VMAX?
provides migrations of live workloads to new VMAX AF systems from older VMAX systems without going offline
What are vVols?
make storage VM centric
allowing provisioning based on performance and storage requirements of the VM
management also performed at volume level
What are the Host IO Limits on VMAX?
feature used to limit the amount of FE bandwidth/IOPS that can be consumed by a set of devices over specific ports
What is included in the FX software package?
D@RE
SRDF/S
SRDF/A
SRDF/Multisite
SRDF/Metro
eNAS
Unisphere 360
PowerPath - 75 Hosts
CloudArray Enabler
SRM
AppSync Advanced
What is CloudArray Enabler?
provides connectivity of VMAX with Dell EMC CloudArray
additional hardware packs required to enable CloudArray
What comes in the zF software package?
HYPERMAX OS
eManagement
TimeFinder SnapVX
Mainframe Essentials
What are the optional parts of the zF software package?
SRDF
D@RE
Unisphere 360
AutoSwap
zDP
Mainframe Essentials Plus
GDDR
What is included in Mainframe Essentials Plus?
includes features like zBoost PAV Optimizer for improved performance on high performance FICON (zHPF) multi-track IO
What is included in the zFX software package?
All zF features
SRDF
D@RE
Unisphere 360
zDP
AutoSwap
What are the optional features on the zFX software package?
GDDR
Mainframe Essentials Plus
What is inside of a vBrick?
an engine and 2 DAEs
What is in the Engine in VMAX?
contain two director boards that are configured identically within the engine
What is located within the Directors?
have supporting cache for the system
in rear of director board modules used for FE host, BE disk and inter-engine connectivity
What is the KVM on VMAX 950F?
installed in System Bay 1
provides service access to the system for onsite service activities
service tray available in all other bays for remote connectivity from service laptop
How are Ethernet Switches connected in VMAX 950F?
located in System Bay 1
provides connectivity to each engine and IB Switches for environmental communications
What is the configuration for each Ethernet Switch in VMAX 950F?
each is a 16 port unmanaged switch w/ a single power supply
cabling to the switches is port specific
Ethernet A cables are green and Ethernet B cables are violet
What are the flexible racking options on VMAX 250F?
one or two systems can be installed in a single rack
What are the restrictions on VMAX 250F racking?
lower portion of rack is reserved for the first system and upper portion for second
How is VMAX 950F racked?
minimum dual engine bays
contains up to 2 engines per bay, a supporting power subsystem, and up to 4 DAEs
How are DAEs attached in a VMAX 950F?
all 4 DAEs are direct attached - two to each engine
What are unique components of a bay of a dual engine VMAX 950F system?
KVM
System Bay 1
- pair of Ethernet switches for internal communications
- pair of IB switches for fabric interconnect between engines
System Bays 2-4
- work tray providing option to connect service laptop