Pool Cert Flash 5. Chemical Tests Flashcards
What factors must be met to ensure all tests are performed to the most accurate standard?
- Follow manufacturer’s instructions. 2. Testing eqt. must be clean. 3. Reagents less than 1 year old and supplied by manufacturer of the tests. 4. Reagents and Colorimeter should be kept away from direct sunlight and intense heat.
Where should you gather your water sample to ensure a proper representation of the pool water?
The side is okay, but must not be by a pool inlet from the filters.
Why are OTO (ortho-tolidine) tests not allowed as replacements for DPD tests?
Time factores, interfering substances, and turbid water can produce inaccureate chlorine test results.
What must Bromine residual levels be held between?
2.0 and 8.0 ppm
If water level exceeds 85 degrees F, what is the minimum level free chlorine and bromine residuals must be held at?
2.0 and 4.0 ppm
What is the temperature range that indoor pools must be held between?
76 and 92 degrees F.
What is turbidity?
The degree to which suspended particles in pool water obscure visibility.
What is the ideal cyanuric acid level between?
25 and 50 ppm.
What must the pH level in the pool be between?
7.2 and 7.6
The DPD Chlorine Test indicates there is no chlorine in the pool, but the chlorinator is on and operating. Why does this happen?
Usu. an indication of too much chlorine in water, causes DPD to bleach out. Repeat test with diluted sample (fill half of vial with pool water, half with distilled). For a 1 to 1 dilution, multiply by appropriate factor (2). For a 1:2 dilution, multiply by (3).
The DPD chlorine test sample turns cloudy when the first reagent is added. Will the test work?
Yes. Sample clouds usu. when first DPD reagent is added to water with high levels of hardness (precipicates calcium). Cloudiness will not affect test results, will disappear soon.
When testing for pH, why do I get a blue/purple color instead of a yellow to red color when using phenol red?
A false pH reading may occur when high levels of chlorine (> 10 ppm) are present. Phenol red is converted to chlorphenol red, which is dark purple when water is alkaline. To eliminate chlorine interference, add 1 drop of chloring neutralizer (thiosulfate) before adding the indicator.
Test kits use chemical _____ to perform the chemical tests necessary for pool operation.
Reagents
An instrument that compares the color of the testing solution with a manufactured color standard is called a:
Colorimeter
The State of Illinois requires the _____ type colorimeter test be used to measure the disinfectant residual.
D-P-D (Diethyl-P-Phenylene Diamine)